Operating Instructions
Single-pole conductor-rail system
SingleFlexLine Program 0815
The following technical requirements must always be strictly observed for the installation:
The maximum permissible traversing speed of the consumer is up to 600 m/min depending on the system
The conductor-rail must only be fitted horizontally
Electrical engineering operational requirements
The electrical system must be secured in compliance with the locally applicable regulations

2.5 Use other than the intended use

Claims of any kind due to damage incurred during use that deviates from the intended use described above ("use other than the
intended use") are excluded. The operator bears sole liability for all damage that result from improper use.
Uses other than the intended use particularly include the following types of use:
Operating the system outside the specified operating conditions (see Chapter 3.3).
Installation in an area accessible to the public.
Operation within manual reach
Use in non-industrial applications
Overloading of the conductor-rails by excessive current or voltage
Overloading of individual current collectors by excessive current or voltage
Operation at excessively high or low temperatures
Operating under ambient conditions that cause lasting damage to the materials used or drastically reduce insulating properties
(e.g., chemical substances or gases)
Operation under prohibited ambient conditions (see the prescribed ambient conditions depending on the product range)
Operation in areas where flammable or explosive gases or dusts prevail
Operation in areas that require a higher protection class than IP 2X
Use as a walking or climbing aid
Walking on the conductor-rail
Use of unsuitable cleaning agents (e.g., silicone oils or aromatic compounds)
Use of the system with accessories that have not been certified and have not been approved by the manufacturer.
Operation of the system by untrained personnel.
The conductor-rail system must only be operated under the environmental conditions detailed in chapter 3! Unsuitable ambient
conditions are described in chapter 3.3