Intel R2000WT Series System Integration And Serive Manual page 139

Hide thumbs Also See for R2000WT Series:

Advertisement

Intel
Server System R2000WT Product Family System Integration and Service Guide
®
Code
Associated Sensors
1-5-2-1
No CPUs installed or first CPU socket is
empty.
1-5-2-4
MSID Mismatch
1-5-4-2
Power fault
1-5-4-4
Power control fault (power good assertion
timeout).
1-5-1-2
VR Watchdog Timer sensor assertion
1-5-1-4
Power Supply Status
Table 11. Integrated BMC Beep Codes
Reason for Beep
CPU1 socket is empty, or sockets are populated
incorrectly
CPU1 must be populated before CPU2.
MSID mismatch occurs if a processor is installed
into a system board that has incompatible power
capabilities.
DC power unexpectedly lost (power good dropout)
– Power unit sensors report power unit failure
offset
Power good assertion timeout – Power unit
sensors report soft power control failure offset
VR controller DC power on sequence was not
completed in time.
The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is
present that is an incompatible model with one or
more other PSUs in the system.