Page 1
Product Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel ® Server System and install components. If you are not familiar with ESD [Electrostatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
Optical Drive Bay CPU1 Air Duct Hard Drive Bays CPU4 Front Control Panel * 3.5" Hard Drive Bay system as shown Useful Information: • The SCU1 (4-7) port requires an Intel RAID C600 Upgrade Key installed to be functional. ®...
General Installation Process The installation instructions in this section are for common components of Intel® Server System R2000LH2/LT2 Product Family. Minimum Hardware Requirements Preparing System To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Observe normal ESD (Electrostatic Discharge) •...
The heatsink is attached to the server board and/or processor socket with captive fasteners. further, check your Using a #2 Phillips* screwdriver, loosen the four screws located on the Intel ® Server System heatsink corners in a diagonal manner using the following procedure:...
NOTE: Heatsink styles may vary. a maximum of 8 inch-lbs torque. Install Memory Modules ...continued Intel® Server Board S4600LH2/LT2 Memory Configurations and Population Order: For best performance, a minimum of four DIMMs per CPU is CPU 2 Socket CPU 1 Socket recommended, populated in the blue slot of each memory channel.
General Installation Process Install Memory Modules ...continued To Install DIMMs: CAUTION: Avoid touching contacts Open both DIMM socket levers. when handling or installing DIMMs. Note location of alignment notch. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. Push down firmly on the DIMM until it snaps into place and both levers close.
Page 10
General Installation Process Install Hard Drives ...continued 3.5" Hard Drive Carrier (For system with 3.5" hard drive bay only) Remove the four Remove the drive carrier screws securing the by pressing the green HDD interface bracket button and opening the and remove the HDD lever.
Page 11
General Installation Process Internal Fixed 2.5" SSD Drive Carrier A. Remove the Rack Handles B. Slide the Front End Module Remove the six screws securing the front end module from the chassis. Slide the front end of Remove the two screws securing the module forward a the rack handle from the chassis little.
Connect the cables is required to maintain proper as shown. system cooling. Install Intel® I/O Expansion Module (optional) Remove the screw securing the filler panel from chassis and remove it. Position the module over the server board, fit the back of the module into the back panel slot.
General Installation Process Install Air Duct Bend and slide in the air duct. Install the air duct into the chassis. Flip-down the tilt bay. NOTE: Take care to avoid pinching system cables. Install Add-in Card(s) For Half-length PCI Add-in Card(s) Remove the filler panel from the add-in card slot and install the provided proper bracket as shown.
Push on the board edge above the connector to ensure the connector is seated. Install Intel® RAID Smart Battery (optional) NOTE: Please refer to the installation instructions shipped with battery for the cable installation. Locate the mounting holes inside the chassis and reposition all cables routed over the fan bulkhead.
NOTE: The FRUSDR utility must be run for full platform management functionality. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel Server System ®...
Link/Act HSBP I Fan Board Power Front Panel Video Front Panel PDB Signal Main Power 1 Main Power 2 IPMB Power Power Reset Button Button See your Intel Server System R2000LH2/LT2 Service Guide for expanded component and connection information. ®...
Page 17
System Fan Connection FAN 11 FAN 9 FAN 10 FAN 8 System Fan Board FAN 7 FAN 6 FAN 5 FAN 4 FAN 3 FAN 2 FAN 1 A complete list of accessories and spares can be found at http://www.intel.com/p/en_US/support/.
Page 18
Reference System Cabling Diagram For System with 4 x 3.5" Hard Drive Bay NOTES: • To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be installed. ® For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
Page 19
Reference System Cabling Diagram For System with 8 x 2.5” Hard Drive Bay: NOTES: • To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be installed. ® For instructions, see Intel RAID C600 Upgrade Key Installation Guide.