Intel R2000BB series Quick Installation User's Manual

Hide thumbs Also See for R2000BB series:

Advertisement

Quick Links

Intel® Server System R2000BB Family
Quick Installation User's Guide
Thank you for buying an Intel® Server System. The following information will help you
assemble your Intel ® Server System and install components.
If you are not familiar with ESD [Electrostatic Discharge] procedures used during
system integration, see the complete ESD procedures described in your Service Guide.
This guide and other supporting documents are located on the web at:
http://www.intel.com/support.
2.5" hard drive bay system as shown
*
G48801-002

Advertisement

Table of Contents
loading

Summary of Contents for Intel R2000BB series

  • Page 1 Intel® Server System R2000BB Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel ® Server System and install components. If you are not familiar with ESD [Electrostatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
  • Page 2 ( This page is intentionally left blank. )
  • Page 3: Table Of Contents

    Install Add-in Card Riser Assembly ................8 Install Rack Handles ......................8 Install Intel® I/O Expansion Module (optional) ............. 8 Install Intel® RAID C600 Upgrade Key (optional) ..........8 Install Intel® RAID Smart Battery (optional) ............8 Install Intel® Remote Management Module 4 (optional) ........ 9 Install Second Power Supply Module (optional) ..........
  • Page 4 Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2012, Intel Corporation. All rights reserved.
  • Page 5: System Overview

    • The system must be configured with two CPUs to enable PCIe slot 1 (Top) and PCIe slot 2 (middle) on Riser #2. • The mini-SAS connector labeled SCU_1 requires an 8-port SATA/SAS Intel RAID C600 Upgrade Key to be functional.
  • Page 6: General Installation Process

    General Installation Process The installation instructions in this section are for common components of Intel® Server System R2000BB family. Minimum Hardware Requirements Preparing the System To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Observe normal ESD (Electrostatic Discharge) •...
  • Page 7: Install The Processor(S)

    General Installation Process Install the Processor(s) Cautions: A. Open the B. Open the C. Remove the Processor Socket Lever Load Plate Protective Cover 1. When opening a socket, Push the lever handle DO NOT TOUCH the gold Push the rear tab with your Take the processor down and away from the socket wires.
  • Page 8: Install Processor Heatsink(S)

    NOTE: For additional memory configurations, see the Service Guide on the Intel Server Deployment & Management DVD that accompanied your Intel ® ® Server System, or go to http://www.intel.com/support. Memory sizing and configuration is supported only for qualified DIMMs approved by Intel. For a list of supported memory, go to http://serverconfigurator.intel.com.
  • Page 9: Install Hard Drives

    General Installation Process Install Memory Modules ... Continued To Install DIMMs: CAUTION: Avoid touching contacts Open both DIMM socket levers. when handling or installing DIMMs. Note location of alignment notch. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. Push down firmly on the DIMM until it snaps into place and both levers close.
  • Page 10 General Installation Process Install Hard Drives ... Continued 3.5" Hard Drive Carrier (For system with 3.5" hard drive bay only) Remove the four screws securing the Remove the drive carrier by pressing the green button plastic drive blank and remove the and opening the lever.
  • Page 11: Install Optical Drive

    General Installation Process Install Optical Drive Install the plastic guide onto the back Insert the optical drive into chassis opening IMPORTANT NOTE: If you do not and push all the way until it stops. install a device at this location, of the drive and attach with two screws install the optical device bay filler as shown.
  • Page 12: Install Add-In Card Riser Assembly

    NOTE: Rack handles are required to install the bezel. For detailed instructions, see the Squeeze the sides of the I/O module product Service Guide available on the Intel ® Server Deployment & Management DVD. bay filler plate, and pull it away from the chassis back panel.
  • Page 13: Install Intel® Remote Management Module 4 (Optional)

    General Installation Process Install Intel® Remote Management Module 4 (optional) Installing the Intel® RMM4 Lite Installing the Intel® RMM4 NIC Locate the RMM4 Lite connector close to the Riser Slot 2, carefully Push out and remove the metal cover on the chassis where the NIC RJ-45...
  • Page 14: Finishing Up

    Note: The FRUSDR utility must be run for full platform management functionality. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel ®...
  • Page 15: Reference

    C. LAN-1 Activity LED H. HDD Activity LED D. LAN-3 Activity LED I. LAN-4 Activity LED B C D E E. System Cold Reset Button J. LAN-2 Activity LED Intel® Server Board R2000BB Component Layout Status Diagnostic Video LEDs ID LED NIC4 NIC3...
  • Page 16 System Fan Connection CPU1 Socket CPU2 Socket FAN 1 FAN 2 FAN 3 FAN 4 FAN 5 * NOTE: System FAN connector 5 on the server board is not used. A complete list of accessories and spares can be found at: http://www.intel.com/support.
  • Page 17 Reference System Cabling Diagram For system with 8 x 3.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be ® installed. For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
  • Page 18 For system with 12 x 3.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be installed. For instructions, ® see Intel RAID C600 Upgrade Key Installation Guide. ® Intel ®...
  • Page 19 Reference System Cabling Diagram For system with 8 x 2.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be ® installed. For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
  • Page 20 For system with 16 x 2.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be installed. For instructions, ® see Intel RAID C600 Upgrade Key Installation Guide. ® PCIe RAID...
  • Page 21 Reference System Cabling Diagram For system with 24 x 2.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key must be ® installed. For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
  • Page 22 G48801-002...

Table of Contents