Page 1
® Intel Server System R2000LH2/LT2 Family Service Guide ® A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Order Number: G42282-005...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life-saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine ® der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel ® Serverplatinen und Servergehäusen auf der Intel Server Deployment Toolkit 3.0 CD oder unter http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
Page 4
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System R2000LH2/LT2 Service Guide...
® and instructions on how to add and replace components on the Intel Server System R2000LH2/LT2 family products. For the latest revision of this manual, go to http://www.intel.com/p/en_US/support.
Page 6
Use this Document or Software compatibility For system power budget guidance Power Budget Analysis Tool ® ® For software to manage your Intel Server Intel Server Management Software System. See the section on the web page titled, “Software/Code”. For system firmware updates and onboard...
Removing the PCI Riser Assembly .................... 22 Installing the PCI Riser Assembly ....................22 Installing and Removing a PCI Add-in Card..................23 Installing a PCI Add-in Card ...................... 23 Removing a PCI Add-in Card..................... 24 ® Intel Server System R2000LH2/LT2 Service Guide...
Page 8
Installing and Removing a Slimline Optical Drive ................35 Installing a Slimline Optical Drive ..................... 35 Removing a Slimline Optical Drive ................... 36 ® Installing and Removing the Intel I/O Expansion Module ..............36 ® Before Installing Intel I/O Expansion Module at the Left Edge of the Board (Optional) ..37 ®...
Page 9
Appendix E: Intel Server Issue Report Form ..................66 Appendix F: Warranty ..........................70 ® Limited Warranty for Intel Chassis Subassembly Products ............... 70 Extent of Limited Warranty........................70 Warranty Limitations and Exclusions ....................70 Limitations of Liability ....................... 71 How to Obtain Warranty Service ......................
Page 10
List of Figures List of Figures ® Figure 1. Intel Server System R2000LH2/LT2................. 1 ® Figure 2. Intel Server System R2000LH2/LT2 Components .............. 3 Figure 3. 3.5" Hot Swap Hard Drive Bay - 4 Drive Configuration ............4 Figure 4. 2.5" Hot Swap Hard Drive Bay - 8 Drive Configuration ............4 Figure 5.
Page 11
Figure 61. Installing Intel I/O Expansion Module................38 ® Figure 62. Removing Intel I/O Expansion Module ................. 39 ® Figure 63. Installing the Intel RMM4 Lite ..................40 ® Figure 64. Installing the Intel RMM4 NIC ..................40 ® Figure 65. Removing the Intel RMM4 NIC ...................
Page 12
List of Tables List of Tables ® Table 1. Intel Server System R2000LH2/LT2 family product list .............. v Table 2. Server System References....................... v ® Table 3. Intel Server System R2000LH2/LT2 Feature Summary ............... 1 Table 4. Wattage Limitation of the PCIe Loading ..................3 Table 5.
Server System Features 1 Server System Features ® This chapter briefly describes the main features of the Intel Server System R2000LH2/LT2 family. This includes illustrations of the products, a list of the server system features, and diagrams showing the location of important components and connections on the server systems.
Page 14
® Quad port 1 GbE based on Intel Ethernet Controller I350 Optional I/O Module ® Dual port 10GBase-T Ethernet module based on Intel Ethernet Controller I350 – Support AXX10GBTWLIOM ® Dual SFP+ port 10GbE module based on Intel 82500 10 GbE controller –...
This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components. ® Figure 2. Intel Server System R2000LH2/LT2 Components ® Intel...
NMI Button (recessed, tool required for use) Power Button w/Integrated LED NIC-1 Activity LED Hard Drive Activity LED Not Used Not Used System Cold Reset Button NIC-2 Activity LED Figure 5. Front Panel Options ® Intel Server System R2000LH2/LT2 Service Guide...
RMM4 NIC Port (Optional) Video Connector Power Supply Module #2 NIC – 1 Power Supply Module #1 NIC – 2 Add-in adapter slots from Riser Card RJ45 Serial-A Port Figure 6. Back Panel Feature Identification ® Intel Server System R2000LH2/LT2 Service Guide...
(Option) I/O Module connector Main Power Slot #2 (Option) eUSB Solid State Device (SSD) connector Main Power Slot #1 Rear System Fan #2 connector CPU #3 DIMM slots – Memory Banks J and K ® Intel Server System R2000LH2/LT2 Service Guide...
4 Port SATA/SAS connector (Drives 4-7) CPU #2 Fan connector 4 Port SATA/SAS connector (Drives 0-3) Fan board power connector ® (Option) Intel RAID C600 Upgrade Key connector PDB signal connector Type-A USB 2.0 connector 4-pin IPMB connector (Option) mSATA port LCP connector 2 Stacked USB 2.0 ports...
BIOS Default (J75) operation. If pins 2-3 are selected, the ME Force Update Mode is enabled. ME Force Update (J81) These pins should be selected on 1-2 for normal system operation. Figure 8. Configuration Jumpers ® Intel Server System R2000LH2/LT2 Service Guide...
R2304LH2/LT2 3.5" or 2.5" R2208LH2/LT2 2.5" ® ® Note: SAS drives are only supported when proper Intel RAID C600 Upgrade Key or Intel Integrated RAID Module is installed. For instructions on installing hard drives, see Installing and Removing Hard Drive.
Slimline DVD-ROM Drive: AXXSATADVDROM Slimline DVD-RW Drive: AXXSATADVDRWROM Note: For a complete list of supported peripherals, go to http://serverconfigurator.intel.com/sct_app.aspx. Bezel The front bezel is available as optional accessory for the server system: Figure 10. Front Bezel (Front View)
It also provides Remote KVM Redirection and USB Media Redirection allowing USB devices attached to the remote system to be used on the managed server. ® For instructions on installing the Intel Remote Management Module 4, see Installing and ®...
Note: Red lines are for power connection, dot lines are for optional device connection. For system with 4 x 3.5" hot swap hard drive bay Note: ® 1. To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key ® must be installed. For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
Hardware Installations and Upgrades For system with 8 x 2.5" hot swap hard drive bay Note: ® 1. To activate the port SCU1 (4-7) on the server board, a proper Intel RAID C600 Upgrade Key ® must be installed. For instructions, see Intel RAID C600 Upgrade Key Installation Guide.
Hardware Installations and Upgrades Fan Connections Use the figures below to determine the proper fan connections. Figure 17. System Fan Order Figure 18. Connecting the Fan Power Cables to the Fan Board and PDB ® Intel Server System R2000LH2/LT2 Service Guide...
1. Lock the right end of the front bezel to the rack handle (see letter A). 2. Rotate the front bezel clockwise till the left end clicks into place (see letter B). 3. Lock the bezel if needed. Figure 20. Installing the Front Bezel ® Intel Server System R2000LH2/LT2 Service Guide...
1. Slide in the bezel (see letter A). . 2. Secure the bezel to the chassis with the two screws on left and right end as shown (see letter B). Figure 22. Installing the Front Fan Bezel ® Intel Server System R2000LH2/LT2 Service Guide...
Align the rack handle with the two holes on the side of the server system and attach the rack handle to the server system with two screws as shown. Figure 24. Installing the Rack Handle ® Intel Server System R2000LH2/LT2 Service Guide...
You will need to remove the top cover to add or replace components inside of the server. Before removing the top cover, power down the server and unplug all peripheral devices and the power cable(s). ® Intel Server System R2000LH2/LT2 Service Guide...
Place system cover onto the chassis and slide forward to engage recessed edge at front of cover (see letter A). Tighten the screw at front (see letter B). Figure 28. Installing the System Cover ® Intel Server System R2000LH2/LT2 Service Guide...
1. Push the front end module into place (see letter A). 2. Secure the front end module with six screws (see letter B). Figure 30. Installing the Front End Module 3. Connect any required cables, please refer to Cable Routing. ® Intel Server System R2000LH2/LT2 Service Guide...
2. Press down the release lever to install the riser assembly into the riser socket (see letter B). 3. Push on the board edge above the connector to ensure the connector is seated. Figure 32. Installing the PCI Riser Assembly ® Intel Server System R2000LH2/LT2 Service Guide...
2. Insert add-in card until it sits in the riser connector (see letter B). 3. Secure add-in card with screw as shown (see letter C). Figure 33. Installing a Half-Length PCI Add-In Card ® Intel Server System R2000LH2/LT2 Service Guide...
2. Remove the PCI add-in card from the riser card connector (see letter B). Figure 35. Removing a Half-Length PCI Add-In Card Note: Make sure that all empty add-in card slots have filler panels installed. ® Intel Server System R2000LH2/LT2 Service Guide...
2. Remove the system cover. For instructions, see Removing the System Cover. 3. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. 4. Remove the power supply modules. For instructions, see Removing the Power Supply Module(s). ® Intel Server System R2000LH2/LT2 Service Guide...
1. Bend and slide in the air duct (see letter A). 2. Install air duct into the chassis (see letter B). 3. Flip down the power supply (see letter C). Figure 38. Installing the Air Duct ® Intel Server System R2000LH2/LT2 Service Guide...
1. Open the Socket Lever. Push down the lever handle on the OPEN 1st side and away from the socket to release it (see letter A). Repeat the steps to release the lever on the other side (see letter B). ® Intel Server System R2000LH2/LT2 Service Guide...
Page 40
Note: The underside of the processor has components that may damage the socket pins if installed improperly. Processor must align correctly with the socket opening before installation. DO NOT DROP processor into socket! 4. Remove the Cover. Press the cover to remove it. Save the protective cover. ® Intel Server System R2000LH2/LT2 Service Guide...
Each heatsink has four captive fasteners and should be tightened in a diagonal manner using the following procedure: 3. Using a #2 Phillips* screwdriver, start with screw 1 and engage screw threads by giving it two rotations and stop (see letter C). (Do not fully tighten.) ® Intel Server System R2000LH2/LT2 Service Guide...
5. Remove the air duct. For instructions, see Removing the Air Duct. Installing Memory 1. Locate the DIMM sockets. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (see letter A). ® Intel Server System R2000LH2/LT2 Service Guide...
Installing a Hard Disk Drive into 3.5" Hot Swap Hard Drive Carrier 1. Remove the drive carrier by pressing the green button and opening the lever (see letter A). Slide the carrier out (see letter B). ® Intel Server System R2000LH2/LT2 Service Guide...
Secure the bracket with three screws as shown (see letter d2). Slide the 2.5" HDD into the bracket to align the screw holes with the right and left rail (see letter d3). Secure the hard disk drive using the four screws for 2.5" HDD (see letter d4). ® Intel Server System R2000LH2/LT2 Service Guide...
Installing a Hard Disk Drive into 2.5" Hot Swap Hard Drive Carrier 1. Remove the drive carrier by pressing the green latch to unlock (see letter A). Pull out the black lever and slide the carrier out (see letter B). ® Intel Server System R2000LH2/LT2 Service Guide...
Figure 55. Installing Hard Disk Drive – Installing 2.5" HDD 4. With the lever open, insert the hard disk drive assembly into the chassis, then push in the lever to lock it into place (see letter F). ® Intel Server System R2000LH2/LT2 Service Guide...
Figure 57. Installing the Plastic Guide to the Optical Drive 2. Insert the optical drive into chassis opening and push all the way until it stops (see letter B). Connect the cables as shown (see letter C). ® Intel Server System R2000LH2/LT2 Service Guide...
Installing and Removing the Intel I/O Expansion Module ® ® Before installing or removing the Intel I/O expansion module, please make sure following steps are performed. 1. Ensure the AC power cord(s) are disconnected from the system. 2. Remove the system cover. For instructions, see Removing the System Cover.
1. Install the module to the provided bracket (see letter A). 2. Secure the module to the bracket with the three screws (see letter B). 3. Install the provided connector converter (see letter C). ® Figure 60. Installing Intel I/O Expansion Module Installing Intel I/O Expansion Module ®...
Hardware Installations and Upgrades ® Figure 61. Installing Intel I/O Expansion Module Removing Intel I/O Expansion Module ® 1. Remove the two screws as shown (see letter A). 2. Remove the module out of the server system (see letter B and C).
Installing and Removing the Intel Remote Management Module 4 ® Before installing or removing the Intel Remote Management Module 4, please make sure following steps are performed. 1. Ensure the AC power cord(s) are disconnected from the system. 2. Remove the system cover. For instructions, see Removing the System Cover.
Installing the Intel RMM4 Lite ® Locate the RMM4 Lite connector next to onboard NIC port, carefully pick up the Intel RMM4 Lite module, and match the alignment pin of the module and the connector on server board. Press to install.
2. Remove the two screws as shown and remove the module out of the server system (see letter B). 3. Remove the cable to the server board (see letter C). ® Figure 65. Removing the Intel RMM4 NIC Installing and Removing an Internal Solid State Drive Before installing or removing the Solid State Drive, please make sure following steps are performed.
Remove the four screws to release the Solid State Drive (see letter D). Pull the Solid State Drive up to remove from the carrier (see letter E). Secure the Solid State Drive carrier to chassis with the two screws. ® Intel Server System R2000LH2/LT2 Service Guide...
® Installing the Intel RAID Smart Battery ® 1. Connect the cable between the BBU and the RAID card. For details, see Intel RAID Smart Battery User’s Guide. 2. Position the battery against chassis (see letter A). 3. Align the tabs on the plastic battery holder with the mounting holes in the chassis and slide in the plastic battery holder until the tabs engage with the mounting holes (see letter B).
Hardware Installations and Upgrades ® Figure 68. Installing the Intel RAID Smart Battery ® Removing the Intel RAID Smart Battery 1. Slide out the plastic battery holder (see letter A). 2. Lift the battery up to remove it from the server chassis (see letter B).
Installing or Replacing the Processor. 8. Remove the memory. For instructions, see Removing Memory. ® ® 9. Remove all the Intel I/O expansion module(s). For instructions, see Removing Intel I/O Expansion Module. ® 10. Remove Intel Remote Management Module 4. For instructions, see Installing and Removing the ®...
6. Locate the battery on the server board. 7. Gently press the metal clip as shown to release the battery (see letter A). 8. Remove the battery from the plastic socket (see letter B). ® Intel Server System R2000LH2/LT2 Service Guide...
2. Pull system fan straight up to remove it from the fan holder. 3. Replace the system fan by guiding it into the slot and firmly pressing down to ensure that it is properly seated. ® Intel Server System R2000LH2/LT2 Service Guide...
1. Hold the backplane only by the edges. Do not push or pull on any components on the backplane. Position the backplane in place at the front of the server system (see letter A). ® Intel Server System R2000LH2/LT2 Service Guide...
Removing the Lower Fan Board 1. Disconnect all cables from the lower fan board. 2. Remove the screws (see letter A). 3. Remove the lower fan board from the server chassis (see letter B). ® Intel Server System R2000LH2/LT2 Service Guide...
2. Secure the lower fan board with the screws as shown (see letter B). Figure 77. Installing the Lower Fan Board 3. Connect cables to the lower fan board; please refer to Cable Routing. ® Intel Server System R2000LH2/LT2 Service Guide...
2. Insert the front video and USB module into chassis (see letter B). 3. Secure the front video and USB module to chassis with two screws (see letter C). 4. Install the video and USB cables to the server board as shown (see letter D). ® Intel Server System R2000LH2/LT2 Service Guide...
3. Insert the LCP module into chassis (see letter B). 4. Secure the LCP module to chassis with two screws (see letter C). 5. Install the LCP and USB cables to the server board as shown (see letter D). ® Intel Server System R2000LH2/LT2 Service Guide...
4. Remove the two screws as shown, slide the front USB header out (see letter D). 5. Install the front video and USB module. For instructions, see Installing the Front Video and Module. ® Intel Server System R2000LH2/LT2 Service Guide...
Install the System into Rack (Optional) Caution: The maximum recommended server weight for the rack rails can be found at http://www.intel.com/support/motherboards/server/sb/CS-033655.htm. Exceeding the maximum recommended weight or misalignment of the server may result in failure of the rack rails holding the server.
1. Pull release button to remove inner member from slides. 2. Align brackets to desired vertical position on rack and insert fasteners. 3. Move ball retainer to the front of slides. Figure 83. Install Slides to Rack ® Intel Server System R2000LH2/LT2 Service Guide...
Figure 85. Install Chassis to Fixed Slides Removing the Chassis from Rack 1. Fully extend the slides until it is in the locked position, pull the release button to release lock and disconnect inner member from slides. ® Intel Server System R2000LH2/LT2 Service Guide...
Hardware Installations and Upgrades Figure 86. Extend Slides 2. Press safety locking pin to release inner member from chassis. Figure 87. Remove Inner Member from Chassis ® Intel Server System R2000LH2/LT2 Service Guide...
To enter the BIOS Setup using a keyboard (or emulated keyboard); press the <F2> function key ® during boot time when the OEM or Intel logo is displayed. The following message is displayed on the diagnostics screen and under the Quiet Boot logo screen: Press <F2>...
This screen text is a hyperlink to its corresponding Field Description. The text shown in the Option Values and Help Text entries in each Field Description are the actual text and values are displayed on the BIOS Setup screens. ® Intel Server System R2000LH2/LT2 Service Guide...
Configuration PCI Configuration Serial Port Configuration USB Configuration System Acoustic and Performance [With BMC Only] Configuration [Non-BMC Only] Hardware Monitor Realtime Temperature and Voltage [Non-BMC Only] Status Security Screen (Tab) ® Intel Server System R2000LH2/LT2 Service Guide...
Page 73
Network Device Order BEV Device Order Add EFI Boot Option Delete EFI Boot Option Boot Manager Screen (Tab) Error Manager Screen (Tab) [Non-BMC Only] View Event Log Screen Exit Screen (Tab) ® Intel Server System R2000LH2/LT2 Service Guide...
Appendix A: Regulatory and Compliance Information Appendix A: Regulatory and Compliance Information Please refer to the Server Products Regulatory and Safety document for the product regulatory compliance reference. The document can be downloaded from http://www.intel.com/support/motherboards/server/. ® Intel Server System R2000LH2/LT2 Service Guide...
Appendix B: Safety Information Appendix B: Safety Information Please refer to the Server Products Regulatory and Safety document for the Safety Information. The document can be downloaded from http://www.intel.com/support/motherboards/server/. ® Intel Server System R2000LH2/LT2 Service Guide...
Appendix C: Installation/Assembly Safety Instructions Appendix C: Installation/Assembly Safety Instructions Please refer to the Server Products Regulatory and Safety document for the Installation/Assembly Safety Instructions. The document can be downloaded from http://www.intel.com/support/motherboards/server/. ® Intel Server System R2000LH2/LT2 Service Guide...
Channel Program members around-the-clock 24x7 technical phone support on ® ® Intel server boards, server chassis, server RAID controller cards, and Intel Server Management. Note: You must login in to the reseller site to obtain the 24x7 number.
® Appendix E: Intel Server Issue Report Form ® Appendix E: Intel Server Issue Report Form Issue Report Form (Rev 3.6) Note: Filling out this form completely is required for any escalation. Customer Contact Information: Customer Support Case# : Intel Server Board or System: ®...
Page 79
Thermal solution (heatsink) examples: (1U, Passive w/air ducting, and so on) Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? Add-in adapters (Example: NICs, Management Adapters, Serial Expansion Cards, PCI-Express* Adapters, RAID Controllers, SCSI Controllers, and so on): Type Slot Manufacturer...
Page 80
® Appendix E: Intel Server Issue Report Form Manufacturer Model Type Size Firmware In Hot Swap Bay? Operating System Information (Example: RedHat* Enterprise Linux, Microsoft Windows Server 2003* Service pack 1, OEM CD): Manufacturer: Version: Language version (English, Arabic, and Chinese (Simplified)):...
Page 81
Steps to replicate the issue: Issue impact statements: Do you have any potential Intel system, or component purchases that this issue is holding up? If yes, please provide a brief description below. Do you have systems already purchased that are not being delivered to your customers because of this issue? If yes, please provide a brief description below.
's publicly available specifications for a period of three ® (3) years after the date the Product was purchased from an Intel authorized distributor. Software of any kind delivered with or as part of products is expressly provided "as is" unless specifically provided for otherwise in any software license accompanying the software.
Limited Warranty, the English language version shall control. How to Obtain Warranty Service ® To obtain warranty service for this Product, you may contact Intel or your authorized distributor. North America and Latin America: To obtain warranty repair for the product, please go ...
Need help?
Do you have a question about the R200LH2 and is the answer not in the manual?
Questions and answers