Timing The Forming Unit/1St Turntable - Sacmi PMV 224 Maintenance And Operation Manual

Machine for forming liners inside plastic caps
Table of Contents

Advertisement

8.2.1.1

Timing the forming unit/1st turntable

- Remove a spindle from the forming unit (3).
- Insert the tool (8) in its place.
- Loosen the screws (16) which secure the wheel of the 1st turntable (2).
- Put the centering ring (7) in a cavity that holds a cap.
- Turn the wheel until the centering ring (7) is centered in relation to the tool (8).
- This may not happen for two reasons:
a) The two halves of the turntable's wheel are not properly set.
During machine testing the two wheels are set, secured in place with screws (14) and drilled so that they can be
correctly positioned with a special fixture without having to remove the sensing spindle.
b) The 1st transfer turntable is not timed with the forming unit.
- In case "a", simply:
- loosen the screws (14);
- correctly position the two parts of the wheel with the tool provided;
- fully tighten the screws (14) again.
- In case "b", simply:
- turn the quality control unit until it is in the correct position;
- fully tighten the screws (16).
FIGURE 8.2.1.1 - TIMING THE FORMING UNIT/1ST TURNTABLE
2
1st transfer turntable
3
Forming unit
7
Centering ring
8
Tool
16 Screw
Revision 01 Date 14.11.2001
3
176.12
MAINTENANCE
7
14 16
2
8
.A03
8
T2430
8 - 19

Hide quick links: