2.3
MACHINE SPECIFICATIONS
2.3.1
TECHNICAL DATA
PRODUCTION RATE
(P.E-EVA-PVC Free)
AIR
Usage (at 0.55 MPa)
Minimum pressure required
POWER
Heat to be dissipated
Power requirements (50Hz)
Power requirements (60Hz)
Average power absorbed (50Hz)
COOLANT
Water
Propylene glycol
Flow rate
Pressure
(2)
TOTAL WEIGHT
At a room temperature of 28 °C and temperature of coolant at 0 °C
(1)
(2
The machines are shipped and delivered disassembled, as indicated in the INSTALLATION chapter.
Revision 01 Date 14.11.2001
(1)
PMV224
(20 kg/h)
up to caps/min.
1200
l/min
1200
MPa
0.5
kcal/h
25,000
kVA
51
kVA
57
kW
12
60%
40%
l/min
60-70
MPa
0.25-0.3
kg
4700
.
176.12
MAIN FEATURES
PMV224
(40 kg/h)
1600
1200
0.5
25,000
62
70
14
60%
40%
60-70
0.25-0.3
5200
.A03
2
PMV238
(40 kg/h)
800
1200
0.5
25,000
62
70
14
60%
40%
60-70
0.25-0.3
5200
2 - 13