4.3.2
CONNECTING THE PNEUMATIC SYSTEM
IMPORTANT!
E0004P
The machine's pneumatic unit must be connected to
the mains air supply by observing all regulations
currently in force in the country where the machine is
installed.
4.3.2.1
Pneumatic unit
Connect a hose with internal diameter as indicated in the
specifications paragraph running from the compressed air
mains supply to the fitting (A).
4.3.2.2
Plastic compound feeder
- Use the hose (B) (6-8 mm dia.) to connect the plastic
compound feeder (if provided) to the point shown in the
figure.
4.3.2.3
Extruder head plunger
Connect the hose (E) (10-12 mm dia.), running from solenoid
valve YV6 in the pneumatic unit, to the corresponding
extruder head cylinder as indicated in the diagram.
FIGURE 4.3.2.3 - EXTRUDER HEAD PLUNGER
T0390
Revision 01 Date 14.11.2001
E
FIGURE 4.3.2.1 - PNEUMATIC UNIT
FIGURE 4.3.2.2 - PLASTIC COMPOUND FEEDER
176.12
INSTALLATION
A
B
.A03
4
T2415
T0391
4 - 11