176.12
.A03
ADJUSTMENTS
7
FIGURE 7.4.2/B - PMV 238 STRIPPER HEIGHT ADJUSTMENT
FORMING WITHOUT CAP
4
2
1
Lower plunger
2
Shim
3
Cap
7.4.3
PLUNGER TEMPERATURE SETTING
Cooling fluid circulates inside the forming plungers. The temperature of the fluid varies according to the type of plastic
compound being used. Normally, the coolant temperature is determined during machine commissioning. To change
the temperature, alter the set point from the control keyboard, as directed in the INSTRUCTIONS B Manual.
7 - 16
Revision 01 Date 14.11.2001
1
4
Stripper
5
Spring
6
Mobile bush
FORMING WITH CAP
5
6
4
3
2
1
5
6
T0631