Adjusting The Height Of The Sensing Equipment And Central Sensor - Sacmi PMV 224 Maintenance And Operation Manual

Machine for forming liners inside plastic caps
Table of Contents

Advertisement

176.12
.A03
ADJUSTMENTS
7
7.5.1

ADJUSTING THE HEIGHT OF THE SENSING EQUIPMENT AND CENTRAL SENSOR

These adjustments must be carried out on a work-bench.
First of all, remove the sensors from the machine by performing the following steps:
- Loosen the nut (3).
- Loosen the stay bolt (4)
- Raise the rod (5)
- Disconnect the coupling (7)
- Remove the sensor (6)
- Position the sensor (6) on the reference plate (9).
- Position the eccentric pin (13) in the intermediate position so that small adjustments can subsequently be made in
both directions.
- Mark the front part of the sensors (1 & 2) with suitable ink.
- Gently bring a lined sample cap into contact with the marked part of the sensor by exerting light pressure and turning
it (the number on the liner should correspond to the number of the sensing spindle to be adjusted).
- Check the liner to see whether the internal (1) or the external part (2) is in contact.
The liner should touch both the central sensor (1) and the external part (2) to an equal extent.
To obtain this condition, loosen or tighten the central sensor (1) as required.
- Set the comparator (10) , mounted on the central sensor (1) to "zero".
- Screw in the sensor until the comparator reads a movement of 0.05 to 0.06 mm.
- Observe measurement "X" when the adjustment procedure has been completed.
- Make sure the sensors are all positioned by using the same measurement "X".
Once the adjustments have been made, refit all of the sensors on the quality control unit.
- Put in the coupling (7).
- Secure the spindle (6) to the rod (5) making sure that the stop (which prevents rotation) is in its correct position.
- Tighten the stay bolt (4) and the nut (3).
FIGURE 7.5.1/A - QUALITY CONTROL UNIT
3
5
6
7 - 18
Revision 01 Date 14.11.2001
3
Nut
4
Stay bolt
5
Rod
6
Sensor
7
Quick coupling
4
7
T0435
FIGURE 7.5.1/B - CENTRAL SENSOR
1
Central sensor
2
External sensor
6
Sensor
9
Reference plate
10 Comparator
x
1
6
9
10
2
T0647

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmv 238

Table of Contents