Table of Contents

Advertisement

4
Fill the cap with washing liquid.
• Use a syringe to draw up some washing liquid and fill until it almost overflows from the cap.
5
Close the front cover, then press the [ENTER] key.
• Pump tube (ink discharge channel below the cap) washing starts.

Media Sensor Cleaning

Media sensors are located on the rear cover and carriage underside. The media cannot be detected
correctly if dust or debris accumulates on the sensors. Remove any debris using cotton swabs or a soft cloth.
Rear of product
l Cleaning the carriage underside sensor
1
In LOCAL mode, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.
3
Open the maintenance covers.
Carriage underside
95