5
Remove the cap absorber.
• Push up the two tabs at the front to remove the cap absorber.
• Avoid ink dripping when removing the cap absorber.
6
Clean the carriage base.
7
Attach a new cap absorber.
• Push the tabs on the cap absorber into the slits at the rear of the C slider, and clip in the tabs at
the front.
Tab
8
Once replacement is complete, close the front cover, then turn on the power.
• Check to confirm that the carriage returns to the station.
Cap absorber
Carriage base
Cap absorber
107
Chapter 4 Maintenance
Push in to engage tab.