Chapter 5 Dealing with Problems
Error
Message
number
509
HDC POSCNT
50a
Y Org Detect Error
50c
Media Width Sensor
50f
L-SCALE BLACK
516
Media Set Position R
525
Wrong Ionizer
526
Ionizer Ion Level
527
Ionizer Condition
528
Pump Motor Sensor
52f
Carriage Org
530
Station Org
536
Station Lock
549
LEnc. Count DIO
608
Wrong Ink IC
64C
NCU Error
650
NCU CONNECT
Cause
• A problem was detected with
position control.
• A problem was detected with
Y origin detection
(initialization).
• A problem was detected with
media width detection.
• A problem was detected with
the linear scale.
• The media was loaded
outside the range of valid
positions.
• The ionizer internal circuit is
defective, or an abnormal
discharge occurred.
• The amount of generated
ions was reduced by fouling
and abrasion of the electrode
needle.
• Ambient conditions may
cause ions to be absorbed by
metals in the vicinity and
affect discharge capability.
• A problem was detected with
the pump motor.
• The carriage control origin
has not been set.
• The station control origin has
not been set.
• A problem was detected with
the station.
• A problem was detected with
the linear scale wiring to the
DIO PCB.
• An error occurred with the
information on the ink IC
chip.
• The function is disabled due
to an error.
• A problem was detected with
the NCU connection.
126
Corrective action
2.
Open the front cover and check for
anything that may obstruct carriage
movement.
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
1.
Check the media loading position.
"Loading the Media"(P. 53)
2.
Clean the media width sensor.
"Media Sensor Cleaning"(P. 95)
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
1.
Check the media loading position.
"Loading the Media"(P. 53)
2.
Clean the media width sensor.
"Media Sensor Cleaning"(P. 95)
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
• Refer to the instruction manual for the
ionizer and clean the electrodes.
• Remove any conductors or discharge
devices close to the ionizer.
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
1.
Check to confirm the ink IC chip was
inserted correctly.
2.
Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
3.
Replace with new ink.
• Turn off the power on the machine and
turn it on after a while.
the Power"(P. 31)
"Turning Off
"Turning Off
"Turning Off
"Turning Off
"Turning Off
"Turning Off
"Turning Off
"Turning Off
"Turning Off

Hide quick links: