•Analogue I/O unit parameters (1)
Parameter
No.
(H.T. Symbol)
The power
Generates error
supply short
per unit when the
circuit
short circuit of the
1
detection for
input device power
the input or
supply or output
output device
device is detected.
(SC_MonSs)
Analogue
Sets the analogue
input or output
input or output
2
range
device range per
(Range)
channel.
Sets analogue data
Analogue
type which is
3
data format
output to master
(D_Format)
per unit.
Sets analogue
Analogue
filtering time per
4
average filter
channel.
(Filter)
Sampling interval is
approx. 2 sec.
Generates error
Over range
per unit when the
5
detection
input value
(Over_Rng)
exceeds 0.5% of
full span.
Generates error
Under range
per unit when the
6
detection
input value falls
(Undr_Rng)
below 0.5% of full
span.
Generates error
User's set
per channel when
value upper
the input or output
limit error
value exceeds the
(Upr_Lmt)
set value.
Sets the scale
7
upper limit.
Scale upper
Generates error
∗ 1
limit setting
per channel when
(UpLm/Scl)
the input or output
value exceeds the
upper limit.
Definition
Item
Enable
Disable
0..10 V
0..5 V
1..5 V
0..20 mA
4..20 mA
Offset binary
Sign &
Magnitude
2s complement
Scaled
None
2AVG
4AVG
8AVG
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Content
Generates an error.
Does not generate an
error.
Selects the analogue
input or output range
Offset binary.
Signed binary.
2's complement.
Scale conversion type.
None
2 value average
4 value average
8 value average
Generates an error.
Does not generate an
error.
Generates an error.
Does not generate an
error.
Generates an error.
Does not generate an
error.
Generates an error.
Val: -32766 to 32767
Does not generated an
∗ 3
error.
Val: -32766 to 32767
-51-
Parameter
setting
Default
By
setting
Ether
CAT
○
○
1..5 V
○
○
○
○
○
○
○
○
○
∗ 2 ∗ 3
○
○
∗ 3
○
Val: 1000
No.EX##-OMO0027
By
H.T.
○
○
○
○
○
○
○