(4)Mounting the valve plate.
Mount the valve plate (EX600-ZMV ) to the valve manifold using the valve set screws. (M3 x 8)
Apply 0.6 to 0.7 Nm tightening torque to the screws.
Screw mounting place
SV
: 2 places
S0700
: 2 places
VQC1000: 2 places
VQC2000: 3 places
VQC4000: 4 places
SY
: 2 places
 
(5)Connect the SI unit to the valve manifold.
Insert the valve plate into the valve plate mounting groove on the side of the SI unit.
Fix using the valve plate screws (M4 x 6) supplied, to a torque of 0.7 to 0.8 Nm.
●Precautions for handling
•Please do not connect the unit while the power supply is active. It will cause equipment
damage.
•Take care not to drop the nuts of Joint bracket.
-11-
No.EX##-OMO0027