•Digital input unit parameters
Parameter
No.
(H.T. Symbol)
The power
Generates error
supply short
per unit when the
circuit
short circuit of the
1
detection for
power supply for
control and
the input device is
input
detected.
(SC_MonSs)
Generates error
Open circuit
per channel when
∗ 1
2
detection
the disconnection
(OC_Mon)
of the input device
is detected.
Ignores excess
Inrush current
current per unit for
3
filter
100 msec. after
(Inrush)
inrush.
Sets the time to
Input filtering
ignore the input
4
time
signal change per
(Filter_T)
unit.
Input
Sets the time to
extension
5
hold the input
time
signal per unit.
(SigExt_T)
Memorizes the
number of times
Channel
the input device is
ON/OFF
ON. Generates
6
counter
error per channel
(Counter)
when the operation
count exceeds the
set value.
∗1: Disconnection detection is a parameter only available for Digital unit (EX600-DXPC1, EX600-DXNC1) with disconnection detection.
∗2: 2-wire type input equipment cannot be correctly detected if its leakage current is 0.5 mA or less while the equipment is in the OFF state
(reed sensor, etc.).
Ensure that all input equipment used has a leakage current above 0.5 mA in the OFF state.
3-wire type input equipment cannot be correctly detected if its current consumption is 0.5mA or less.
The open circuit of input signals cannot be detected.
∗3: The count is memorized every hour. When the power supply is turned on again, counting starts from the last value memorized.
∗4: Times for setting is set value x1000 times.
 
Definition
Item
Enable
Disable 
Enable
Disable 
∗ 2
Enable
Disable 
0.1 ms
1.0 ms 
10 ms 
20 ms 
1.0ms
15 ms 
100 ms 
200 ms 
Enable
Disable 
∗ 3
Content
Generates an error.
Does not generate an
error. 
Generates an error.
Does not generate an
error. 
Ignores excess current.
Does not ignore excess
current. 
Selects the time for
filtering.
Selects the time to hold
the input signal.
Generates an error.
∗ 4
Val: 1 to 65000
Does not generate an
error. 
-43-
Parameter
setting 
Default
By
setting
By
Ether
H.T.
CAT
 
○ 
○ 
1.0 ms
15 ms
○ 
No.EX##-OMO0027