3. Setting up the PDS-220Fx Module

This chapter provides detailed information about the "Self-Test" process, which is used to confirm
that the PDS-220Fx Series is operating correctly. Before beginning the "Self-Test" process, the
wiring test, Ethernet configuration and VxComm utility driver installation procedures must first be
fully completed. Follow the procedure described below:
3.1 Connect the Power Supply and the Host PC
1.
Ensure that the network settings on your PC are configured correctly.
2.
Ensure that the Windows firewall or any Anti-Virus firewall software is correctly configured or
temporarily disable these functions; otherwise the
Utility may not work as required. You may need to contact your System Administrator for
more details of how to do this.
3.
Connect both the PDS-220Fx via the Fiber Optic Converter (e.g., NS-200AF Series, Optional)
and Host computer to the same sub-network or the same Ethernet Switch.
4.
Short the "TxD+" to "RxD+" and "TxD-" to "RxD-" pins on the COM2
PDS-220Fx for self-test.
Ethernet to Fiber
Optic Converter
TxD
RxD
Ethernet
Cable
Short TxD-
and RxD+
PDS-220Fx Series User Manual
"Search Servers"
function in the VxComm
terminal block on the
Front Panel
Fiber
Rx
Tx
Short TxD+
and RxD+
Version 1.3, Oct. 2018
Figure 3-1
- 23 -