Programmable Serial-to-Fiber Device Server

7.3.6 SystemTimeout

This command queries or sets the system timeout value.
If the SystemTimeout is greater than zero, and the PDS-220Fx does not receive any packets from
any client for longer than the SystemTimeout period, the PDS-220Fx will reboot itself.
Effect: Immediate
Command
Arguments
SystemTimeout
SystemTimeout
= nnnnn
The figure illustrates is an
Figure 7-3-6:
example of a SystemTimeout configuration.

7.3.7 SocketTimeout

This command is used to query or set the SocketTimeout parameter.
If the SocketTimeout is greater than zero, and the PDS-220Fx does not receive any data from a
client PC for longer than the SocketTimeout period, the PDS-220Fx will close the socket connection
between itself and the client PC.
Effect: Immediate
Command
Arguments
SocketTimeout
SocketTimeout
= nnnnn
The figure illustrates is an
Figure 7-3-7:
example of a SocketTimeout configuration.
Description
Queries the SystemTimeout settings.
Sets the SystemTimeout. (Unit : ms)
Default factory setting is 300000 ms (= 300 seconds = 5 minutes )
Min. value is 30000 ms (= 30 seconds)
Description
Queries the SocketTimeout settings.
Sets the SocketTimeout. (Unit : ms)