Programmable Serial-to-Fiber Device Server

7.3.4 COM

This command queries or sets the configuration of the COM Ports (Baud Rate/Parity/Stop bits).
Effect: Immediate
Command
Arguments
com
com
n
com
N= BaudRate,
DataBits,
Parity,StopBit(s)
The figure illustrates is an example of a COM configuration.
Figure 7-3-4:

7.3.5 Broadcast

This command is used to Enable/Disable listening broadcast packets on PDS-220Fx.
Effect: Immediate
Command
Arguments
Broadcast
Broadcast
= 1
Broadcast
= 0
The figure illustrates is an example of a Broadcast configuration.
Figure 7-3-5:
Description
Queries the configuration of all COM Ports.
Queries configuration of COM Port "n".
If n = 0, the configuration of all COM Ports will be listed in the same way as
using the command "com" above.
Sets the configuration of COM Port "n".
If n = 0, the settings will be valid for all Com Ports on the PDS-220Fx.
Description
Queries the Broadcast settings.
Sets Broadcast = 1. The system is able to receive broadcast packets.
Sets Broadcast = 0. The system will ignore broadcast packets.
PDS-220Fx Series User Manual
Version 1.3, Oct. 2018
- 81 -