ICP DAS USA PDS-220F Series User Manual page 64

Programmable serial-to-fiber device server
Hide thumbs Also See for PDS-220F Series:
Table of Contents

Advertisement

Programmable Serial-to-Fiber Device Server
Step 2: Configuring the PDS-220Fx #2 in Server Mode
1. Enter the URL address of the PDS-220Fx #2 in the address bar of the browser or click the "Web"
button in the VxComm Utility to log in to the web configuration page.
2. Click the "COM Port Settings" tag to enter the settings page, and select the appropriate COM
Port number, Baud Rate and Data Format settings from the relevant drop down options, for
example "115200", "8", "None" and 1" .
3. Check the "Save current settings to EEPROM" and "Apply Current settings" items, and then
click the "SET COM
4. Click "Set Remote VCOM3 connection" at the PDS-220Fx #2 (Server) COM PORT setup page.
Refer to Figures 5-3-2 to 5-3-6 for illustrations of how to perform the Steps 1 to 4.
5. Confirm that the Local COM port/Remote COM port area of the PDS-220Fx #2 (Server) is
"None".
Notes:
1. The baud rate and data format settings of the client and server (PDS-220Fx #1 and #2) are depending on
COM ports of the connected device. The serial port settings can be different between the PDS-220Fx #1
and #2.
2. PDS-220Fx Pair-connection: Built-in serial software buffer, baud rate and data format must be configured
on PDS-220Fx first.
3. I-2541 Pair-connection: No serial software buffer, baud rate and data format cannot be configured on I-2541.
PORT"
button to finish configuration.
PDS-220Fx Series User Manual
Figure 5-3-9
Version 1.3, Oct. 2018
- 64 -