Clock Set - Henny Penny CFE 415 Service Manual

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Mode
Provides
T T - - 2 2 1 1
AIF Info
T T - - 2 2 2 2
Pumps and
Valves
Operation and
Display
generally recom-
mended, unless one in-
tends to completely
reset all the statistics
data.
This initialization func-
tion will cause the con-
troller to activate Clock
Set mode at the next
power up, and to also
ask IS THIS NEW
OIL?.
AIF ✓✓ 20
- AIF ✓: Means normal
communications be-
tween the AIF PCB and
the control PCB. - AIF
XX: Means a problem
with the communica-
tions between the
PCBs.
Press the down-arrow,
and LIGHTS DLT_
displays.
Press the down-arrow,
and VALVES DcRc
displays.
Press 7 to open and
close the return valve: -
DcRc means valve is
closed.
- DcRo means valve is
open.
Press the down-arrow,
DISCARDc / JIBFILLc
displays:
- Press 1 to open /
close the RTI discard
valve. DISCARDo dis-
plays when open.
- Press 2 to open /
close the RTI JIB fill
valve. JIBFILLo dis-
plays when open.
Press the down-arrow,
PUMP FP_ / JP_ NP_
displays:
Description
101