Henny Penny CFE 415 Service Manual page 101

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Display
"E-70"
Faulty power switch or switch wir-
"PWR SW OR
ing; faulty I/O board.
WIRES FAILED"
"E-75"
Normal wear on secondary
"HEAT RELAY
contactor.
NEAR END OF
LIFE"
"E-92"
Blown 24 volt controller fuse, or
"24 VOLT FUSE"
bad 14-pin cable connection.
Cause
or control PCB board, if
necessary.
Have power switch checked,
along with its wiring; have I/O
board checked
Have heat contactor replaced.
Have the 14-pin cable connector
or fryer checked for a short to
ground in components such as
the drain switch, or high limit and
wiring.
Correction