Mode
Provides
T T - - 8 8
LED's Display
Test
T T - - 9 9
Pot Temp Cali-
bration & Offset
T T - - 1 1 0 0
Level Temp Cali-
bration & Offset
Operation and
Display
LEDS
This step tests each in-
dividual discrete LED.
The test pattern is as
follows: Wait, Ready,
Left timer, Heat, Info,
Down, Up, Prog, Right
Timer, L1, L2, L3, L4,
L5, L6, R1, R2, R3, R4,
R5, R6.
Press and release any
number button to step
through the test se-
quence manually, or
press and release the
timer button to run the
test sequence auto-
matically one time
through.
CALIB/OFFSET/
View/set calibration off-
HIGHEST:
set for temperature
- Press and hold [1]:
probe and view/reset
CALIB ADJ 357°F
max recorded pot
- Press and hold [2]:
temperature:
OFFSET ADJ +2°F
- UP/DOWN to adjust
- Press and hold [3]:
calibration viewed as a
HIGHEST 367°F
temp.
- UP/DOWN to adjust
calibration viewed as
an offset.
- View highest re-
corded pot
temperature.
Reset max temp by
pressing the DOWN
button while viewing.
CALIB/OFFSET/
View/set calibration off-
HIGHEST:
set for temperature
- Press and hold [1]:
probe and view/reset
CALIB ADJ 87°F
max recorded pot
- Press and hold [2]:
temperature:
OFFSET ADJ +0°F
- UP/DOWN to adjust
- Press and hold [3]:
calibration viewed as a
HIGHEST 121°F
temp.
- UP/DOWN to adjust
calibration viewed as
an offset.
Description