Henny Penny CFE 415 Service Manual page 69

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Menu
13. Pot Temp.
14. Level Temp.
15. Protection Temp.
16. CPU Temp.
17. Analog Info
<1> 2344
18. AC VOLTS
Description
2 2 . . Press the program button to continue onto the Pot
Temperature reading.
This step shows the present oil temperature. The display
shows "13. POT TMP (temp)".
1 1 . . Press the program button to continue onto the Level
Temperature reading.
This step shows the present level probe temperature.
1 1 . . Press the program button to continue onto the
Protection Temperature reading.
This step shows the present protection probe temperature.
1 1 . . Press the program button to continue onto the CPU
Temperature reading.
This step shows the present PC board temperature.
1 1 . . Press the program button to continue onto the
Analog reading.
This step displays the present status of any channel of the
controller's a-to-d converted. This feature may be useful to
a technician troubleshooting the fryer or controller.
1 1 . . The displayed value can be toggled between volts
and bits by pressing product selection 1. If the
displayed value has a decimal point, it is voltage (0 to
5 VDC). If no decimal point is shown, the value is a-
to-d bits (0 - 4095).
2 2 . . Press the program button to continue onto AC Volts
reading.
This step displays the present status of the line voltage
supply to the fryer. This displayed value is averaged over a
10 second period, so brief dips or fluctuations in the
voltage might not show up in the display.
1 1 . . The voltage is normally displayed as a "percent of
nominal" value where 100% would indicate that
voltage is right on the nominal value (i.e. 208 volts for
a 208v fryer). The display can be toggled to an actual
voltage value by pressing product selection 6.