Henny Penny CFE 415 Service Manual page 148

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Note how and where the old temperature probe protrudes through the front side
3 3 ) )
of the vat.
Lower or remove the front control panel as needed for access.
4 4 ) )
Remove front, left or right-side panels as needed for access.
5 5 ) )
Disconnect the temperature probe wire lead, which is located behind the control
6 6 ) )
panel.
Remove the nut connecting the temperature probe to the vat.
7 7 ) )
Apply white Loctite to the threads of the compression nut on the new
8 8 ) )
temperature probe, and then insert thru opening. See
Thermocouple Installation, Right Side , page
Tighten the temperature probe compression nut by hand to snug (zero torque),
9 9 ) )
and then add 1/4 to 1/2 half turn with a wrench. Do not overtighten.
Connect the wire lead.
1 1 0 0 ) )
Install the drain pan, reserve oil tank, reconnect the power, add oil to the vat,
1 1 1 1 ) )
and then run a filter cycle while checking for leaks.
If leaks are discovered, repair as necessary.
1 1 2 2 ) )
Test the temperature probe to ensure it works properly.
1 1 3 3 ) )
Replace all the panels.
1 1 4 4 ) )
9 9 . . 1 1 9 9 H H i i g g h h L L i i m m i i t t T T h h e e r r m m o o c c o o u u p p l l e e s s R R e e p p l l a a c c e e m m e e n n t t
Refer to
Figure 10-5 Thermocouple and Probes , page 150
part number.
Ensure the oil is drained from the vat and drain pan, remove the drain pan and
1 1 ) )
set aside, and then remove the power from the fryer.
Remove the reserve oil tank and set aside.
2 2 ) )
Note how and where the old thermocouple(s) protrudes through the front side of
3 3 ) )
the vat, and then through the spreader bar assembly.
Lower or remove the front control panel as needed for access.
4 4 ) )
Remove the front shroud, left or right-side panels as needed for access.
5 5 ) )
Loosen the Allen screws holding together the spreader bar. Do not remove
6 6 ) )
completely.
Disconnect the thermocouple wire lead, which is located behind the control
7 7 ) )
panel.
Remove the compression nut connecting the thermocouple to the vat.
8 8 ) )
136
U U n n p p l l u u g g t t h h e e f f r r y y e e r r f f r r o o m m t t h h e e p p o o w w e e r r s s o o u u r r c c e e b b e e f f o o r r e e p p e e r r f f o o r r m m i i n n g g
t t h h i i s s p p r r o o c c e e d d u u r r e e . . V V o o l l t t a a g g e e i i s s p p r r e e s s e e n n t t , , w w h h i i c c h h m m a a y y c c a a u u s s e e
s s e e v v e e r r e e i i n n j j u u r r y y . .
Figure 9-12
131.
for location, illustration and

Advertisement

Table of Contents