Henny Penny CFE 415 Service Manual page 92

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Problem
Too dark (all
batches).
Too light (all
batches).
80
Cause
Temperature probe out of
calibration, incorrect heaters,
or improper voltage.
Oil too old.
Oil too dark.
Faulty probe; "E-6".
Temperature probe out of
calibration.
Slow fryer heat-up/recovery.
Correction
Information Mode Details , page 48
4B and 5B, to see what product was
selected.
See D1 of
6.3.1 Diagnostic Mode
Details , page 68
to adjust color of
product.
Check temperature probe
calibration; if less than 15
degrees off, have probe
calibrated (service manual
required); if more than 15
degrees off, replace probe.
Have heating elements checked.
If oil is smoking or has burnt
taste, change oil.
See D2 of
6.3.1 Diagnostic Mode
Details , page
68; change oil if
controls indicate it should be
changed.
If oil is smoking or has burnt
taste, change oil.
Filter oil.
Perform clean-out procedur
Clean-Out Mode , page
If probe can't be re-calibrated, have
probe replaced.
See D1 of
6.3.1 Diagnostic Mode
Details , page 68
to adjust color of
product.
Check temperature probe
calibration; see Check
Temperature Probe Calibration
Section; if less than 15 degree
off, have probe calibrated; if
more than 15 degrees off,
replace probe.
See D4 of
6.3.1 Diagnostic Mode
Details , page
68, for present
day's performance; or see
4.1
33.
6.2