Henny Penny CFE 415 Service Manual page 106

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Mode
T T - - 1 1 1 1
T T - - 1 1 2 2
T T - - 1 1 3 3
94
Provides
Operation and
Pro Temp Cali-
CALIB/OFFSET/
bration & Offset
HIGHEST:
- Press and hold [1]:
CALIB ADJ 87°F
- Press and hold [2]:
OFFSET ADJ +0°F
- Press and hold [3]:
HIGHEST 121°F
CPU Control
CALIB/OFFSET/
Temp Calibration
HIGHEST:
& Offset
- Press and hold [1]:
CALIB ADJ 87°F
- Press and hold [2]:
OFFSET ADJ +0°F
- Press and hold [3]:
HIGHEST 121°F
Fryer Supply
208V NOM
Volts
Description
Display
- View highest re-
corded pot
temperature.
Reset max temp by
pressing the DOWN
button while viewing.
View/set calibration off-
set for temperature
probe and view/reset
max recorded pot
temperature:
- UP/DOWN to adjust
calibration viewed as a
temp.
- UP/DOWN to adjust
calibration viewed as
an offset.
- View highest re-
corded pot
temperature.
Reset max temp by
pressing the DOWN
button while viewing.
View/set calibration off-
set for CPU board tem-
perature and view/
reset max recorded
CPU board
temperature:
- UP/DOWN to adjust
calibration viewed as a
temperature.
- UP/DOWN to adjust
calibration viewed as
an offset.
- View highest re-
corded CPU
temperature.
Reset max by pressing
the DOWN button while
viewing.
View/set the fryer's
nominal line voltage
(Unknown, 120V,
208V, 240V, 480V).

Advertisement

Table of Contents
loading

Table of Contents