Apply white Loctite to the threads of the compression nut on the new
9 9 ) )
thermocouple, and then insert thru opening. See
Installation, Right Side , page
Tighten the thermocouple compression nut by hand to snug (zero torque), and
1 1 0 0 ) )
then add 1/4 to 1/2 half turn with a wrench. Do not overtighten.
Connect the wire lead.
1 1 1 1 ) )
Install the drain pan, reserve oil tank, reconnect the power, add oil to the vat,
1 1 2 2 ) )
and then run a filter cycle while checking for leaks.
If leaks are discovered, repair as necessary.
1 1 3 3 ) )
Test the thermocouple to ensure it works properly.
1 1 4 4 ) )
Replace all the panels.
1 1 5 5 ) )
9 9 . . 2 2 0 0 D D r r a a i i n n P P a a n n M M i i c c r r o o s s w w i i t t c c h h R R e e p p l l a a c c e e m m e e n n t t
Standing in the front of the fryer, the drain pan switch is bolted to the left-rear-bottom
of the frame with two 10-24 serrated edge lock nut. Refer to
Assembly , page 144
for location, illustration and part number.
U U n n p p l l u u g g t t h h e e f f r r y y e e r r f f r r o o m m t t h h e e p p o o w w e e r r s s o o u u r r c c e e b b e e f f o o r r e e p p e e r r f f o o r r m m i i n n g g
t t h h i i s s p p r r o o c c e e d d u u r r e e . . V V o o l l t t a a g g e e i i s s p p r r e e s s e e n n t t , , w w h h i i c c h h m m a a y y c c a a u u s s e e
s s e e v v e e r r e e i i n n j j u u r r y y . .
Ensure the oil is drained from the vat and drain pan, remove the drain pan and
1 1 ) )
set aside, and then remove the power from the fryer.
Using a wrench or ratchet with socket, remove two 10-24 serrated edge lock
2 2 ) )
nuts from beneath the drain switch.
Pull the drain switch out of the back of the fryer, and then disconnect the lead
3 3 ) )
wire by separating the pin connector.
Remove the frame wire ties as necessary to completely remove the drain
4 4 ) )
switch.
Bolt the new drain pan switch in place but leave it loose.
5 5 ) )
Insert the drain pan back in to the fryer.
6 6 ) )
Adjust the drain switch so it is fully engaged.
7 7 ) )
Tighten both 10-24 serrated edge lock nuts, from beneath the drain switch to
8 8 ) )
snug (zero torque), and then add 1/4 to 1/2 half turn with a wrench.
Connect the pin connector.
9 9 ) )
Install the frame wire ties as necessary.
1 1 0 0 ) )
Test the new drain pan switch to ensure it works properly.
1 1 1 1 ) )
9 9 . . 2 2 1 1 W W i i - - F F i i R R a a d d i i o o
Refer to
Table 10-9 Wi-Fi , page 159
Figure 9-12 Thermocouple
131.
for location, illustration and part number.
Figure 10-2 Drain Pan
137