Henny Penny CFE 415 Service Manual page 111

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Mode
Provides
Operation and
Description
Display
all signals to the right
of it to also be missing.
If a V, H, or D signal is
missing and yet other
signals do appear to
the right of it, it is likely
that the voltage sensor
for the missing signal
has failed or that some-
thing is not wired
correctly.
Example: A V _ D S
This example is abnor-
mal, because the H sig-
nal is missing and yet
the D and S signals ap-
pear to the right of it. It
might be that the volt-
age sensor chip for the
H input has failed, or it
might be that the wiring
for the High Limit and
the Drain switch are
incorrect.
T T - - 1 1 8 8
Output Test
Electric: H*
View/set the status of
the controller outputs:
- If an output is cur-
rently on, an asterisk
(*) displays after the ID
letter.
- If an output is cur-
rently off, a line dis-
plays after the ID letter.
Electric:
H = HEAT OUTPUT:
The heat output may
be manually controlled
using the number 1
button.
Under manual control
on either type of fryer,
the Heat output will
shut off automatically if
no buttons are pressed
for 30 seconds.