Drain Pan Assembly - Henny Penny CFE 415 Service Manual

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Problem
Temperature probe out of
calibration.
Slow fryer heat-up/recovery.
With power switch in
Open circuit.
on position, fryer is
completely without
power.
Filter motor runs but
Pump clogged.
pumps oil slowly.
O-rings worn, damaged, or
missing.
Clogged filter envelope
Wet filter envelope
Filter pump motor
Reset filter pump motor
does not run.
Cause
Check temperature probe calibra-
tion; see Checking Temperature
Probe Calibration section; if between
5 and 15 degrees off, calibrate
probe; if more than 15 degrees off,
replace probe.
See D4 of
Details , page 68
day's performance; or see
Information Mode Details , page
48
problem.
Low voltage; see D3 of
Diagnostic Mode Details , page
68
performance; for more
information see
Mode Details , page 48
P P o o w w e e r r S S e e c c t t i i o o n n
Check to see if fryer is plugged
in.
Check wall circuit breaker or
fuse.
Have a qualified service
technician check power supply
and power switch.
F F i i l l t t e e r r S S y y s s t t e e m m S S e e c c t t i i o o n n
Have pump cleaned.
Replace drain pan o-ring
terly Drain Pan O-Ring Replace-
ment , page
Clean drain pan, empty crumb bas-
ket, and replace filter envelope
Drain Pan Assembly , page
Dry drain pan and replace filter enve-
lope
3.7 Drain Pan Assembly , page
29.
Allow 15 minutes for filter pump mo-
tor to cool, remove the reserve oil
tank, then use the tip of a screw-
driver to press in on the red reset
Correction
6.3.1 Diagnostic Mode
for the present
6.2
for more information on this
6.3.1
for present day's voltage
6.2 Information
4.2.3 Quar-
38.
3.7
29.
83