12. Output Info
OUTP B-S-H*
56
Menu
• A= Power switch turned to on.
• V= Volts - 24 VAC detected.
• H= High Limit - If "H" is present, the high limit is
• D= Drain Switch - If "D" is present, the drain handle
• S= Power switch "on" interlock circuit - if "S" is
• F= Fan.
• M= MV - Detects 24 V jumper to MV terminal.
2 2 . . Press the down button to view the specific status of
each input of each terminal. A "_" indicates the input
is not presently detected. A"" indicates the signal is
detecting a normal input. A blinking "X" indicates the
signal is presently detected, but is detected as a half-
wave (partially failed) input. I I N N F F O O : The V, H, D, S, F,
and M signals below are wired in series. The first
signal missing out of this sequence will generally
cause all signals to the right of it to be missing as
well.
3 3 . . Press the program button to continue onto Output
Info check.
This mode displays the status of components and outputs.
If the output signal is detected, an identifying letter is
displayed (see below), followed by an "*". If the output is
off, "_" is displayed.
B= (not used on this model) S= Safety Contactor Output
H= Heat Contactor Output
If the heat is on, "H" shows in display. If heat is off, "H_"
shows in display. If control senses a problem with the heat
output, "H*" shows in display with the "*" flashing.
1 1 . . Press the down button to view the outputs and inputs
together.
Description
good; if "H" is missing, the high limit is tripped
(overheated) or faulty.
is closed; if "D" is missing, the drain is open or
faulty.
present, the power switch is in the on position; if
the "S" is missing, the power switch is either off,
failed, or wired incorrectly.