Henny Penny CFE 415 Service Manual page 99

Narrow open fryer electric
Hide thumbs Also See for CFE 415:
Table of Contents

Advertisement

Display
"E-5"
Oil overheating.
"FRYER TOO HOT"
"E-6A"
Temperature probe open.
"FRYER TEMP
SENSOR"
"E-6B"
Temperature probe shorted.
"FRYER TEMP
SENSOR
"E-10"
High limit.
"HIGH LIMIT
TRIPPED"
"E-15"
Drain switch.
"DRAIN IS OPEN"
"E-18"
Upper temperature probe open
"LEVEL SENSOR
or shorted.
FAILED"
"E-19"
Protection temperature probe
"PROTECTION
(against heating element) open
SENSOR FAILED"
or shorted.
"E-25"
Wrong or faulty elements, wiring
"HEAT AMPS
problem, setting or configuration
WERE TOO HIGH"
problem.
Cause
Turn switch to off position, then
turn switch back to on; if display
shows "E-5", the heating circuits
and temperature probe should be
checked.
Turn switch to off position, then
turn switch back to on; if display
shows "E-6A", the temperature
probe should be checked.
Turn switch to off position, then
turn switch back to on; if display
shows "E-6B", the temperature
probe should be checked.
Allow heating elements to cool
(15-20 minutes) and reset high
limit by pressing the high limit re-
set button for 3 seconds. If high
limit does not reset, have the
electronic high limit circuit
checked.
Make sure drain knob is com-
pletely pushed-in; if E-15 per-
sists, have drain switch checked.
Turn switch to off position and
then back to on; if display still in-
dicates a failed sensor, have sen-
sor checked.
Turn switch to off position, then
turn switch back to on. If display
shows "E-19", the protection tem-
perature probe should be
checked.
Have electrical supply, wiring,
and elements checked.
NOTICE: Keep fryer off if this er-
ror persists, or wiring damage
could result.
Correction
87