Menu
SP-8
SP-8A
SP-8B
SP-8C
SP-9
SP-10
SP-11
44
Display Name
IDLE MODE
Idle mode enable setting (YES, NO). Press the down
ENABLED?
button to change from YES to NO.
Idle mode regulates the oil at a lower temperature to
save energy and extend shortening life during low de-
mand periods.
If enabled, the Idle mode may be activated either auto-
matically or by manual pushbutton selection, depending
on the [SP‑8B] and [SP‑8C] settings below. Cook mode
is resumed by pressing any product button.
IDLE SETPT
Press up and down buttons to set the temperature (190°
TEMP
F - 380°F) for Idle mode. Default temperature is 250°F.
AUTO-IDLE
Period of inactivity (OFF, 1 - 60 min.) that triggers activa-
MINUTES
tion of Idle mode. This timer starts when the fryer recov-
ers back to set point temperature.
USE 6 FOR IDLE
Manual Idle button enable by pressing the down button
(YES, NO).
If set to YES, and Idle Mode is enabled, then the "6" but-
ton is used as a Manual Idle button: pressing the "6" but-
ton while in Cook mode will immediately activate Idle
(setback) mode.
PRODUCT
1.COOK: Pressing a product button selects and immedi-
BUTTONS
ately starts a cook cycle for that product. The Timer but-
ton is used to stop cook cycles. The appropriate product
button must be pressed each time a cook cycle is
started. This is the default setting.
2.SELECT: Pressing a product button only selects that
product for cooking. The Timer button must be used to
start a cook cycle. The Timer button is also used to stop
a cook cycle. Subsequent cook cycles for the same
product can be started by simply pressing the Timer but-
ton again, as the product is already selected and its
name is shown on the display.
COOKING
Press the down button to select what is displayed during
DISPLAY
the cook cycle:
- TIME = Count Down Timer.
- TM+ID= Timer and Product ID Alternate.
- NM+TM= Product Name and Timer Alternate.
QUALITY TMR
Press the down button to select what displays, if the
quality timer is enabled for products (not used on CFE
415):
- NONE=No Quality Timer Display.
- QT+ID= Quality Timer and Product ID Alternate.
NM+QT= Product Name and Quality Timer Alternate.
Function