5 5 . . 2 2 . . 8 8 S S P P - - 8 8 E E d d i i t t U U n n i i t t S S e e r r i i a a l l N N u u m m b b e e r r
Press the down arrow and "SP-8 S/N ✓EDIT" shows in left display. Press the
1 1 ) )
right ✓ button to enter the unit's serial number in the controls using the product
buttons. "STD" and "CUST" show in the right display. Press the ✓ button under
the "STD" and the first 2 letters of the serial number is the standard equipment
code, press the "X" button and a custom equipment code can be entered.
NOTE: This serial number should match the serial number on the data plate,
located on the door.
5 5 . . 2 2 . . 9 9 S S P P - - 9 9 D D e e c c a a l l L L a a y y o o u u t t
Press the down arrow and "SP-9 DECAL LAYOUT?" scrolls in the left display.
1 1 ) )
The words in the right displays should match the arrow type above the temp and
info buttons. For example, if the control decal shows down-up, the right display
should show "DOWN-UP". If the display shows "UP-DOWN", use the left and
right arrows to change the displays to "DOWN-UP".
5 5 . . 2 2 . . 1 1 0 0 S S P P - - 1 1 1 1 M M e e l l t t C C y y c c l l e e S S e e l l e e c c t t
Press the down arrow and "SP-11 MELT CYCLE SELECT" scrolls in the left
1 1 ) )
display. Unless solid oil is being used in the vats, the right display should show
"1.LIQUID". If solid oil is used, the unit must be equipped to handle solid oil. Use
the left and right arrows to change the right display to "2.SOLID".
5 5 . . 2 2 . . 1 1 1 1 S S P P - - 1 1 2 2 C C h h a a n n g g e e P P a a d d R R e e m m i i n n d d e e r r T T i i m m e e
Press the down arrow and "SP-12 'CHANGE PAD' REMINDER" shows on the
1 1 ) )
display. Use the product buttons to change the time between changing the filter
pad reminders. For example, if "25 HRS is programmed in the right display,
every 25 hours, the display shows "CHANGE PAD" as a reminder to the
operator that the filter pad needs changed.
5 5 . . 2 2 . . 1 1 2 2 S S P P - - 1 1 3 3 P P a a n n O O u u t t O O f f F F r r y y e e r r = = P P a a d d C C h h a a n n g g e e d d
Press the down button and "SP-13 PAN OUT = CHANGED PAD" scrolls in the left
display. Use the product buttons to program the amount of time the drain pan is pulled
out from under the fryer before the controls reset the change pad reminder. This is the
amount of time it should take to change filter pad. Range is 15 to 255 seconds. For
example, if "120 SEC" is programmed in the right display, when the drain pan is out
form under the fryer for at least 120 seconds, the control restarts counting for the
change pad reminder.
5 5 . . 2 2 . . 1 1 3 3 S S P P - - 1 1 4 4 A A u u t t o o - - F F i i l l l l E E n n a a b b l l e e d d
Press the down arrow and "SP-14 AUTO-FILL ENABLED?" scrolls in the left
1 1 ) )
display. Use the left and right arrows to set the right display to "YES" or "NO".
This should always be set to "YES" unless a hardware failure causes a problem,
such as a JIB pump or Add Oil valve failure.
5 5 . . 3 3 C C l l o o c c k k S S e e t t
Press and hold the temp and info button until "LEVEL - 3" shows in the display,
1 1 ) )
followed by "ENTER CODE".
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first two product buttons).
2 2 ) )
"A. TECH" "RESETS" shows in the display. Press the down arrow twice and "C.
3 3 ) )
CLOCK" "SET" shows in the display.