4.11.7 Manual Adjustment for Data Shift

PURPOSE
To make the setting not to use the Head 2 nozzles that overlap with the Head 1 nozzles
in the sub-scanning direction.
Head 1
Figure 4-43. Manual Adjustment for Data Shift
PAPER USED
 Size: 24 inch length or longer
 Type: Premium Glossy Photo Paper (250)
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Load the paper into the printer.
2.
Turn the printer ON.
ADJUSTMENT
Head 2
Overlapping nozzles
Head Related Checks and Adjustments
3.
On the control panel, select the
Media Setup
setting to
RIP Settings
"0".
4.
Start the Service Program and select
5.
Click [Print].
Adjustment pattern is printed.
Figure 4-44. [Manual Adjustment for Data Shift] Screen
6.
Select the pattern with the fewest gap.
C H E C K
Use even numbers only.
P O I N T
7.
Click [Run].
Save the parameter in printer.
8.
Turn off the printer to finish the adjustment work.