SC-F9200 Series
4.10.4 CR Scale Check
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Turn the printer ON.
2.
Start the Service Program and select
3.
Click [Run].
The CR Unit moves left and right four times, and then the CR Encoder starts to
read the scale.
The result is OK: Go to
Step 5
The result is NG: Go to
Step 4
Figure 4-23. [CR Scale Check] Screen
ADJUSTMENT
CR Scale
Check.
CR Related Adjustments
4.
Since the CR Scale is not scanned correctly, clean the scale using ethanol. If the
scale still cannot be read properly, replace the CR Encoder
Scale
(P.
157). After replacing the part, return to
5.
Click [Finish].
6.
Turn the printer OFF to finish the adjustment.
CR Scale
Figure 4-24. CR Encoder and Scale Check
SE Group Confidential (Related Staff Only)
Revision C
(P. 166)
or the CR
Step 3
to check again.
CR Encoder
304