Epson SC-F9200 Series Service Manual page 307

Large format color inkjet printer
Hide thumbs Also See for SC-F9200 Series:
Table of Contents

Advertisement

SC-F9200 Series
Left side of Head
Front
Metal pointer
Metal pointer
Thickness gauge
Print Head 1
Metal pointer
Thickness gauge
Place the thickness gauge while aligning
the left end of the gauge with the metal
pointer.
Figure 4-27. Placing the Thickness Gauge (left side)
6.
Measure the height of the CR Unit to see if it is within the standards.
(Measure at the both left and right of the CR Unit. Right and left set position refer
to
Figure 4-26
and
Figure
4-27)
Within the standards: Cap the Print Head and end the adjustment.
Out of the standards: Go to
Step
ADJUSTMENT
Upper
Print Head 2
Print Head 1
Thickness gauge
Suction hole
Thickness gauge
Set the thickness gauge aligning the top
edge with the upper edge of the suction
holes.
7.
CR Related Adjustments
7.
Move the CR Unit to the left end, and remove the CR Cover.
8.
Loosen the screws that secure the left and right PG adjustment levers.
9.
Move the PG adjustment levers up and down to change the gap (PG).
10. Tighten the screws to secure the PG adjustment levers, and go back to
repeat the procedure until the height of the CR Unit falls inside the standard range.
PG Adjustment Levers
Raise the lever to move the CR up
Lower the lever to move the CR down
Figure 4-28. PG Adjustment Levers
SE Group Confidential (Related Staff Only)
Revision C
(P. 139)
Step
Fixing screws
5, and
307

Advertisement

Table of Contents
loading