Epson SC-F9200 Series Service Manual page 50

Large format color inkjet printer
Hide thumbs Also See for SC-F9200 Series:
Table of Contents

Advertisement

SC-F9200 Series
Code
Error Name
The IC Holder 2 has reached the end of its service
life. (The total number of times the ink cartridge is
1433
IC Holder 2 life error
removed from the printer has reached a predetermined
limit)
The Ink Path CR Assy has reached the end of its
Ink Path CR Assy
1435
life error
service life.
Pump Cap Unit 1
1410
Pump Cap Unit 1 failure
undetectable error
Pump Cap Unit 2
1411
Pump Cap Unit 2 failure
undetectable error
Wrong color ink was filled in the ink tank. This error
Wrong ink mixture
occurs if the combination of the ink holder and the
1417
error
chip unit is not correct.
PG position
When changing the PG, the PG sensor could not
150C
detect the PG position.
undetectable error
The control terminal (Vre terminal) of the APG Motor
APG Motor
1519
driver has shorted out.
oscillation error
Connection failure of the APG Motor.
Overcurrent to the APG Motor was detected.
APG Motor cable is damaged.
APG Motor
151A
overload error
Irregular load
APG encoder failure
APG Motor failure
TROUBLE SHOOTING
Table 2-4. Troubleshooting for Service Call Error
Cause
Is the sensor cable properly connected?
Is the sensor cable properly connected?
Check if wrong color ink is filled (check if the
combination of the ink holder and the chip unit is
correct.)
1. Is the PG Sensor out of order? Does the light
shielding plate react to the sensor?
2. Do the planetary gearing work normally? Do the
planet gears and outer gears properly engage with
each other?
3. Is the CR Unit out of its home position?
1. Is the APG Motor driver on the Main Board
damaged?
2. Is there any foreign materials around the APG
Motor driver?
Is there any problems such as damaged cable in the
connections below?
APG Motor (APG encoder) to Main Board
(CN210/CN203)
Remedies for Service Call Error
Check Item
Replace the IC Holder 2
---
counter
Replace the Ink Path CR Assy
---
the counter
Replace the Pump Cap Unit 1.
Replace the Pump Cap Unit 2.
Discard the current ink tank, and clean the ink path
using cleaning liquid, then install a new ink tank.
(Page 72)
1. Replace the PG Sensor.
2. Replace the APG Assy.
3. Remove any obstacles around the CR Unit home
position. The printer changes the PG with the CR
Unit being at its home position.
1. Remove the foreign material.
2. If the error still occurs, replace the Main Board.
(Page 123)
Replace the APG Motor.
SE Group Confidential (Related Staff Only)
Revision C
Remedy
(Page 189)
and reset the
(Page 293)
.
(Page 140)
and reset
(Page 293)
.
(Page 170)
(Page 177)
(Page 169)
(Page 167)
(Page 167)
50