Configuring the system
2.3 Configuration file "basesys.ini"
; SNMPLocation and SNMPContact are reported for the standard OIDs
; SNMPv2-MIB::sysLocation and SNMPv2-MIB::sysContact, resp.
; SNMPAutLocation and SNMPFunction are used in the Siemens A&D
specific
; AUTOMATION-SYSTEM-MIB as
automationSystemIdent.automationLocationTag
; and automationSystemIdent.automationFunctionTag, resp.
SNMPLocation="not specified"
SNMPContact="not specified"
SNMPAutLocation="not specified"
SNMPFunction="not specified"
SNMPStation=""
[DCP]
; These variables en/disable the DCP protocol on X120/X127
; and X130, resp.
;InternalDcpEnabled=0
;ExternalDcpEnabled=1
[LLDP]
; These variables en/disable the LLDP protocol on X120/X127
; and X130, resp.
;InternalLldpEnabled=0
;ExternalLldpEnabled=1
[LinuxBase]
; Keep size of /var/log/messages around this value
; (not followed exactly for performance reasons)
LogfileLimit=102400
; Protocol/Port pairs to open in the firewall
; (e.g. TCP/5900, UDP/514, ...)
;FirewallOpenPorts=TCP/5900 TCP/102 TCP/22
; If there is only one Ethernet interface, it's used by
; default as an external (company) network. Alternatively,
34
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
NCU operating system