6.3.17
Exit Loading Softkey (EXITLS)
Description
You can use the EXITLS function to exit the current user interface and load a defined softkey
menu.
Programming
Syntax:
Description:
Parameters:
Example
PRESS(HS1)
END_PRESS
6.3.18
Function (FCT)
Description
The external functions are stored in a DLL file and identified by an entry in the definition lines
of the configuration file.
Note
The external function must have at least one return parameter.
Programming
Syntax:
Description:
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1
EXITLS
Exits dialog and loads a softkey menu
Softkey menu
Path name
EXITLS( "Menu1", "AEDITOR.COM" )
FCT
Function name = ("File"/Type of return/Types of permanent parameters/
Types of variable parameters)
FCT InitConnection = ("c:\tmp\xyz.dll"/I/R,I,S/I,S)
An external function can, for example, be called from the LOAD method or exe‐
cuted in the PRESS method.
("Softkey menu"[, "Path "])
Name of the softkey menu to be loaded
Directory path of the softkey menu to be loaded