Attributes of BaseEventType
Attribute
Data type
EventId
String
EventType
NodeId
SourceNode
NodeId
SourceName
String
Time
UtcTime
ReceiveTime
UtcTime
Message
Localized Text
Severity
UInt16
LocalTime
TimeZoneDa‐
taType
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Configuration Manual, 12/2017, 6FC5397-1DP40-6BA1
Mapping with respect to SINU‐
MERIK
Unique node id generated from
SINUMERIK system.
It is always set to 'CncAlarmType'. M
Alarm source identifier provided
by SINUMERIK system.
Supported alarm source names
are HMI, NCK, and PLC.
Alarm time stamp
Alarm time stamp of the server.
Reading attributes via
(SLAE_EV_ATTR_MSG TEXT)
Reading attributes via
(SLAE_EV_ATTR_SEVE RITY)
Offset and the DaylightSavingI‐
nOffset flag
M/O
Description
M
EventId is generated by the Server to
uniquely identify a particular Event Notifi‐
cation.
The EventId shall always be returned as
value and the Server is not allowed to re‐
turn a StatusCode for the EventId indicat‐
ing an error.
The EventType shall always be returned as
value and the Server is not allowed to re‐
turn a StatusCode for the EventType indi‐
cating an error.
M
SourceNode identifies the Node that the
Event originated from. If the Event is not
specific to a Node, the NodeId is set to null.
M
SourceName provides a description of the
source of the Event. This could be the
string-part of the DisplayName of the Event
source using the default locale of the serv‐
er.
If it is not possible for a CNC system to pro‐
vide this information in detail, the Source‐
Name should provide the main component
responsible for this alarm (e.g. CNC, PLC,
or even Channel).
M
Time provides the time of the Event occur‐
red. Once set, intermediate OPC UA Serv‐
ers shall not alter the value.
M
ReceiveTime provides the time the OPC
UA Server received the Event from the un‐
derlying device of another Server.
M
Alarm Message provides a human reada‐
ble and localizable text description of the
Event.
M
Severity of the event message. The range
of values of the severity is from 1 to 1000,
where 1000 corresponds to the highest se‐
verity.
O
LocalTime is a structure containing the Off‐
set and the DaylightSavingInOffset flag.
The Offset specifies the time difference (in
minutes) between the Time Property and
the time at the location in which the event
was issued. If DaylightSavingInOffset is
TRUE, then Standard/Daylight savings
time (DST) at the originating location is in
effect and Offset includes the DST correc‐
tion. If FALSE, then the Offset does not in‐
clude DST correction and DST may or may
not have been in effect.