Factory Setting Of The Windows Firewall On The Siemens Pc System - Siemens SINUMERIK 840DE sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Configuration of the system
4.17 Adapting the firewall settings
4.17.2

Factory setting of the Windows Firewall on the Siemens PC system

The Windows Firewall settings on your Siemens PC system are appropriately configured by
the PCU-Basesoftware for the use of SINUMERIK software and systems. For security reasons,
the Windows Firewall is activated in the company network and expanded by additional rules.
The Windows Firewall is deactivated in the system network. The descriptions in this chapter
therefore largely relate to the adaptation of the firewall settings for the company network.
Table 4-6
Interface
Network name for PCU 50.5
Network profile
Status Windows Firewall
See: General information on the settings
recommended for Windows (Page 70)
File and printer release
See: Activation/deactivation of the file
and printer release (Page 76)
SNMP communication
See: Enabling SNMP communication
(Page 71)
Remote access (via port 5900)
See: Activate the remote access to the
PC system (Page 73)
Outgoing ICMP Ping requests from the
PC system
See: Activation of the ping execution
(ICMP) (Page 88)
Incoming ICMP Ping requests on the PC
system
See: Activation of the ping execution
(ICMP) (Page 88)
Note
Automatic network release of USB data storage media results in activation of the file and printer
release
The automatic network release of USB data storage media is activated in the default setting
of the NCU-Basesoftware. The file and printer release is then activated by Windows when a
USB data storage medium is connected.
See: Configuring network access on the USB data storage medium (Page 34)
See also
Patch management and security updates (Page 96)
Saving and restoring firewall settings (Page 90)
68
Factory settings for network adapter and Windows Firewall
System network
Company network
X2
X1
Local Area Connection Local Area Connection 2
Public
Public
Deactivated
Activated
Activated and permit‐
Deactivated and blocked by firewall
ted
Permitted
Blocked
Permitted
Blocked
Permitted
Permitted
Permitted
Blocked
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
PCU Base Software (IM10)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl