Fcoe Example Configuration - Lenovo Flex System Fabric CN4093 Application Manual

How to configure and use the enterprise nos 8.4 software on the 10 gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

FCoE Example Configuration

1. Configure FCoE ports as trunk ports and add them to FCoE VLAN for FCoE traffic 
2. Turn CEE on.
3. Turn global FIP snooping on:
4. Disable FIP snooping on all non‐FCoE external ports:
5. Enable FIP snooping on FCoE ports, and set the desired FCF mode:
326
CN4093 Application Guide for N/OS 8.4
The following example collects the various components from previous sections of 
this chapter.
Figure 34. A Mixed Fibre Channel and FCoE Network   
802.1p Priority & Usage
3 FCoE Applications
802.1p Priority & Usage
0-2
LAN
4
Business-Critical LAN
Servers
In Figure 34 on page
326, a Fibre Channel network is connected to the CN4093 on 
port EXT22. The FCoE‐enabled CN4093 is internally connected to a blade server 
(ENode) through an FCoE‐enabled CNA on port INTA1. An internal FCF bridges 
the networks.
and any Native VLAN (other than the FCoE VLAN) for FIP negotiation: 
CN 4093(config)# interface port INTA1
CN 4093(config-if)# switchport mode trunk
CN 4093(config-if)# switchport trunk allowed vlan 1,1002 (Add VLANs)
CN 4093(config-if)# exit
CN 4093(config)# cee enable
Note: Turning CEE on will automatically change some 802.1p QoS and 802.3x 
standard flow control settings and menus (see "Turning CEE On or Off" on 
page
302).
CN 4093(config)# fcoe fips enable
CN 4093(config)# no fcoe fips port EXT1-EXT20 enable
CN 4093(config)# fcoe fips port INTA1 enable
CN 4093(config)# fcoe fips port INTA1 fcf-mode off      (Set as ENode connection)
Note: By default, FIP snooping is enabled on all ports and the FCF mode set for 
automatic detection. The configuration in this step is unnecessary if default 
settings have not been changed, and is shown merely as a manual configuration 
example.
FCoE
CNA
FCF
INTA1
Switch
CNA
INTA2
Lenovo Chassis
                            (Exit port configuration mode)
Fibre
EXT22
Channel
Ethernet
EXT1
LAN
 (Select FCoE ports)
 (Enable VLAN tagging)