Binding the New Switch to the Stack

1. Log in to the stack interface.
2. From the stack interface, assign the csnum for the new switch.
© Copyright Lenovo 2017
Note: If replacing the Master switch, be sure to log in to the stack interface (hosted 
temporarily on the Backup switch) rather than logging in directly to the newly 
installed Master.
You can bind Member switches to a stack csnum using either the new switch's 
asnum or MAC address:  
CN 4093(config)# stack switch-number <csnum> universal-unic-id <uuid> bay
<Slot ID>
‐or‐
CN 4093(config)# stack switch-number <csnum> bind <asnum>
‐or‐
CN 4093(config)# stack bind
Note: If replacing the Master switch, the Master will not assume control from the 
Backup unless the Backup is rebooted or fails.