Lldp Transmit Features; Scheduled Interval; Minimum Interval - Lenovo Flex System Fabric CN4093 Application Manual

How to configure and use the enterprise nos 8.4 software on the 10 gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

LLDP Transmit Features

Scheduled Interval

Minimum Interval

544
CN4093 Application Guide for N/OS 8.4
Numerous LLDP transmit options are available, including scheduled and 
minimum transmit interval, expiration on remote systems, SNMP trap notification, 
and the types of information permitted to be shared.
Note: In stacking mode, only the stack Master transmits LLDP information for all 
the ports in a stack. The stack MAC address is used as the source address in the 
LLDP packets.
The CN4093 can be configured to transmit LLDP information to neighboring 
devices once each 5 to 32768 seconds. The scheduled interval is global; the same 
interval value applies to all LLDP transmit‐enabled ports. However, to help 
balance LLDP transmissions and keep them from being sent simultaneously on all 
ports, each port maintains its own interval clock, based on its own initialization or 
reset time. This allows switch‐wide LLDP transmissions to be spread out over 
time, though individual ports comply with the configured interval.
The global transmit interval can be configured using the following command:
CN 4093(config)# lldp refresh-interval <interval>
where interval is the number of seconds between LLDP transmissions. The range is 
5 to 32768. The default is 30 seconds.
In addition to sending LLDP information at scheduled intervals, LLDP 
information is also sent when the CN4093 detects relevant changes to its 
configuration or status (such as when ports are enabled or disabled). To prevent 
the CN4093 from sending multiple LLDP packets in rapid succession when port 
status is in flux, a transmit delay timer can be configured.
The transmit delay timer represents the minimum time permitted between 
successive LLDP transmissions on a port. Any interval‐driven or change‐driven 
updates will be consolidated until the configured transmit delay expires.
The minimum transmit interval can be configured using the following command:
CN 4093(config)# lldp transmission-delay <interval>
where interval is the minimum number of seconds permitted between successive 
LLDP transmissions on any port. The range is 1 to one‐quarter of the scheduled 
transmit interval (lldp refresh-interval <value>), up to 8192. The default is 2 
seconds.