Lenovo Flex System Fabric CN4093 Application Manual page 267

How to configure and use the enterprise nos 8.4 software on the 10 gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

© Copyright Lenovo 2017
The following table compares the configurations of the two modes.
Table 25.
Comparison: Dedicated Mode vs. Shared Mode
Configuration
Dedicated Mode
Area
Port
"tagpvid" must be disabled.
"pvid" = vNIC group VLAN.
"tag" is user configurable. 
Port can be added only to the 
vNIC group VLAN.
Inserts vNIC group VLAN in the 
outer tag of ingress packets.
VLAN
Add the port to a vNIC group 
VLAN and delete it from any 
other VLAN when the vNIC 
group VLAN is enabled.
Delete the port from the vNIC 
group VLAN and add it back to 
the default VLAN 1 when the 
vNIC group is disabled/deleted or 
when the vNIC feature is globally 
disabled.
Do not add a port or LAG to mul‐
tiple vNIC groups that are 
enabled.
Do not configure additional 
VLANs on the uplink ports.
STP
An uplink port can only be in one 
STG.
When you add a port to a vNIC 
group, STP is automatically dis‐
abled. 
When you remove a port from a 
vNIC group, STP is automatically 
reset to factory default.
Failover
An uplink up/event can trigger 
the failover state change only of 
one vNIC group.
Shared Mode
"tagpvid" is user configurable.
"pvid" is user configurable.
"tag" must be enabled.
Port can be added to multiple VLANs 
in addition to the vNIC group VLANs 
that are automatically configured.
Inserts regular VLAN in the outer tag. 
VLAN tags are passed to and received 
from the uplink switch similar to 
vNIC ports.
To handle untagged packets, con‐
figure the pvid/native VLAN of the 
uplink port to one of the vNIC group 
VLANs, and disable "tagpvid".
Add the port to all vNIC group 
VLANs that are sharing the port. Do 
not remove it from any other VLAN.
Remove the port from a vNIC group 
VLAN when the vNIC group is dis‐
abled/deleted. 
When the vNIC feature is globally 
disabled or the port is not added in 
any vNIC group, remove the port 
from all vNIC group VLANs and add 
it back to default VLAN 1 if no 
non‐vNIC VLAN exists on the port.
Can add a port or LAG to multiple 
vNIC groups that are enabled.
Can configure additional VLANs on 
the uplink ports.
An uplink port can be in multiple 
STGs.
When you add a port to a vNIC 
group, STP is automatically disabled.
When you remove a port from a vNIC 
group, STP is automatically reset to 
factory default.
An uplink up/event can trigger the 
failover state change of multiple vNIC 
groups.
Chapter 15: Virtual NICs
267

Advertisement

Table of Contents
loading

Table of Contents