Vlag Configuration - Vlans Mapped To Msti; Configure The Isl - Lenovo Flex System Fabric CN4093 Application Manual

How to configure and use the enterprise nos 8.4 software on the 10 gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

VLAG Configuration - VLANs Mapped to MSTI

Configure the ISL

1. Configure STP:
2. Configure the ISL ports and place them into a portchannel (dynamic or static):
3. Configure VLAG Tier ID. This is used to identify the VLAG switch in a multi‐tier 
4. Configure the ISL for the VLAG peer.
202
CN4093 Application Guide for N/OS 8.4
Follow the steps in this section to configure VLAG in environments where the STP 
mode is MSTP and no previous VLAG was configured.
The ISL connecting the VLAG peers is shared by all their VLAGs. The ISL needs to 
be configured only once on each VLAG peer. Ensure you have the same region 
name, revision and VLAN‐to‐STG mapping on both VLAG switches.
CN 4093(config)# spanning-tree mode mst
CN 4093(config)# interface port 1-2
CN 4093(config-if)# switchport mode trunk
CN 4093(config-if)# lacp mode active
CN 4093(config-if)# lacp key 200
CN 4093(config-if)# exit
CN 4093(config)# vlag isl adminkey 200
Note:
a. In this case, a dynamic LAG is shown. A static LAG (portchannel) could be 
configured instead.
b. ISL ports and VLAG ports must be members of the same VLANs.
environment.  
CN 4093(config)# vlag tier-id 10
Make sure you configure the VLAG peer (VLAG Peer 2) using the same ISL 
aggregation type (dynamic or static), the same VLAN for vLAG ports and vLAG 
ISL ports, and the same STP mode and tier ID used on VLAG Peer 1.