Lenovo Flex System Fabric CN4093 Application Manual page 398

How to configure and use the enterprise nos 8.4 software on the 10 gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

3. Add each IP interface to the appropriate VLAN.
4. Verify the configuration.
398
CN4093 Application Guide for N/OS 8.4
Each time you add a port to a VLAN, you may get the following prompt:
Port 4 is an untagged port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]?
Enter y to set the default Port VLAN ID (PVID) for the port.
Now that the ports are separated into three VLANs, the IP interface for each subnet 
must be placed in the appropriate VLAN. From Table
follows:
CN 4093(config)# interface ip 1
CN 4093(config-ip-if)# vlan 2
CN 4093(config-vlan)# exit
CN 4093(config)# interface ip 2
CN 4093(config-ip-if)# vlan 1
CN 4093(config-ip-if)# exit
CN 4093(config)# interface ip 3
CN 4093(config-ip-if)# vlan 1
CN 4093(config-ip-if)# exit
CN 4093(config)# interface ip 4
CN 4093(config-ip-if)# vlan 3
CN 4093(config-ip-if)# exit
CN 4093(config)# show vlan
CN 4093(config)# show interface information
CN 4093(config)# show interface ip
Examine the resulting information. If any settings are incorrect, make the 
appropriate changes.
35, the settings are made as 
                    (Select IP interface 1)
                   (Add VLAN 2)
                   (Select IP interface 2)
                   (Add VLAN 1)
                   (Select IP interface 3)
                   (Add VLAN 1)
                   (Select IP interface 4)
                   (Add VLAN 3)

Advertisement

Table of Contents
loading

Table of Contents