5. PROGRAMMING

For.commands.and.external.signalling.description,.refer.to.the.User.Manual..The.system.programming.can.be.performed.directly.on.the.control.
panel,.with.buttons.and.a.little.LCD.display,.or.with.a.PC.provided.with.Urmet.EasyPro.1061/001.software.and.connected.to.the.control.panel.
via.the.USB.port.or.a.modem..Some.parameters.concerning.the.PSTn.communicator.can.be.changed.only.via.PC.
5.1 PROGRAMMING PROCEDURE
The.programming.procedure.consists.in.the.following.steps:
1.. Assign.an.address.to.the.bus.devices,.if.not.yet.assigned..
2. Enter in programming mode (if the control panel has never been programmed before, see paragraph 5.3 First power-up).
3.. Program.inputs..
4.. Program.outputs..
5.. Program.partitions..
6.. Program.alarm.times,.entry,.exit,.failure.and.technological..
7. Program keys (master and user).
8. Program codes (master and user).
9.. Assign.keys.to.partitions..
10.. Assign.codes.to.partitions..
11.. Program.PSTn/GSM.communicator..
1.. Record.vocal.messages.
not. all. steps. are. necessary,. because. some. of. them. depend. on. the. presence,. in. the. system,. of. particular. bus. devices. or. control. panel.
expansions.
5.2 CONTROL PANEL HARDWARE PROGRAMING INTERFACE
For programming procedure, as shown in figure 21, on the control panel motherboard are available:
One.-digits,.7-segments.LCD.display..
One.ESC.button.to.return.to.the.previous.menu.level.or.exit.from.programming.mode.in.any.time..
One.↓.button.to.scroll.items.of.the.same.menu.level.(the.menu.items.structure.is.circular:.at.the.last.item,.by.pressing.again.the.button,.it.is.
possible to return to the first one).
One.OK.button.to.select/deselect.a.parameter.or.go.to.a.secondary.menu..
On. the. LCD. display,. the. dot. that. appears. down. on. the. right. side. means. that. the. displayed. value. is. the. one. stored. at. the. moment. for. the.
parameter selected for the configuration.
.
The.result.of.each.programming.operation.is.signalled.by:
A."beep.beep".to.signal.a.successful.programming.procedure..
A.long."beep".to.signal.an.unsuccessful.programming.procedure..
5.3 FIRST POWER-UP
.
At the first power-up:
The inputs LEDs blink in sequence.
On the LCD display appears for 2 seconds the control panel firmware version.
Then.the.LCD.display.starts.blinking..
At.this.moment.perform.as.follows:.
Acquire a key (electronic or transponder) as Master key, by inserting or bring it near a reader.
. Or:.
Enter on the keypad the code that will become the Master code (from 4 to 6 digits, freely selectable) and confirm it by pressing the OK button
on.the.keypad..
If in the system are present both keypads and readers, to acquire a Master key or set a Master code is indifferent. After acquiring the Master key
(or after setting the Master code), the LCD display stops blinking and shows the first item of the main menu. Now it is possible to program the
control panel (go directly to paragraph 5.4.2 Main programming menu).
.
WARNING:. Write the programmed Master code, or mark the acquired Master key, because they are necessary to access to Maintenance
functions.

5.4 SYSTEM CONFIGURATION VIA HARDWARE

5.4.1 ENTERING IN PROGRAMMING MODE
To.enter.in.control.panel.programming.mode,.when.it.has.been.already.programmed.before,.follow.the.instructions.below:.
1.. Activate.the.system.maintenance.mode,.as.described.in.paragraph.7.1.Maintenance.procedure..
.. Keep.the.OK.programming.button.pressed.for.3.seconds..
3. On the LCD display appears for 2 seconds the control panel firmware version.
4. Wait until on the LCD display appears the first item of the main programming menu.
now.it.is.possible.to.program.the.control.panel.(go.to.paragraph.5.4.2 Main programming menu).