Film Size Processed
Only roll films 35 cm wide
Only 35 x 35 cm film
Average size intermix film
Only 35 x 43 cm film
* If sensitometry does not stay within control limits, flooded replenishment may be needed. Order and install
FLOODED REPLENISHMENT KIT 419779.
Note
For more information and for new recommended processing instructions, see SERVICE BULLETIN 30, Pub. No.
632661.

Adjusting the REPLENISHMENT PUMP

BRACKET
2 SCREWS
7C8771 – 04DEC98
Average Amount of Film
Use Condition
PROCESSOR Operation
High
105 Linear feet or more
Medium
35 - 105 linear feet
Low
35 linear feet or less*
High
90 sheets or more
Medium
30 - 90 sheets
Low
30 sheets or less*
High
115 sheets or more
Medium
40 - 115 sheets
Low
40 sheets or less*
High
75 sheets or more
Medium
25 - 75 sheets
Low
25 sheets or less*
TOP COVER
PUMP COVER
H172_1028ACA
H172_1028AC
Setup and Checkout of the PROCESSOR
per 8 Hours of
[1] Remove:
• TOP COVER
• RECEIVING BIN
• 2 SCREWS
• PUMP COVER
Replenishment Flow Rate,
mL per 35 x 43 cm
34 seconds for Standard Cycle
25 seconds for Rapid Cycle
Developer
Fixer
50
65
80
100
50
65
80
100
50
65
80
100
60
80
100
100
120
70
85
70
85
70
85
85
31